11. AUTO CALIBRATION
- 129 -
11.4 AGC
This procedure is for Rx calibration.
In this procedure, We can get RSSI correction value. Set band EGSM and press Start button the result
window will show correction values per every power level and gain code and the same measure is
performed per every frequency.
11.5 APC
This procedure is for Tx calibration.
In this procedure you can get proper scale factor value and measured power level.
11.6 ADC
This procedure is for battery calibration.
You can get main Battery Config Table and temperature Config Table
11.7 Setting
check com port and cable loss. Select automatic calibration item. If you uncheck one item calibration
will stop from the unchecked item. This is useful when you want to process only one item.
11.8 How to do calibration
A. Connect cable between phone and serial port of PC.
B. Connect Ag8960 equipment and Power Supply and phone.
C. Set correct port and baud rate.
D. Press Start button. AutoCal process all calibration procedure
i. AGC EGSM
ii. AGC DCS
iii. APC EGSM
iv. APC DCS
v. ADC
E. After finished all measurement. The state is return to SETUP.
F. The Cal file will be generated and then the calibration data will be written into phone and then will be
reset.
Содержание C3380
Страница 1: ...Service Manual Model C3380 Date November 2005 Issue 1 0 Service Manual C3380 ...
Страница 3: ... 4 ...
Страница 83: ...4 TROUBLE SHOOTING 84 4 11 KEY backlight Trouble Test Points Figure 4 22 ...
Страница 98: ...4 TROUBLE SHOOTING 99 Yes No Yes No Replace M201 Establish a call Replace U101 Software Re_download ...
Страница 109: ...Note 110 ...
Страница 116: ... 117 8 PCB LAYOUT ...
Страница 117: ... 118 8 PCB LAYOUT ...
Страница 125: ...10 STAND ALONE TEST 126 Figure 10 2 HW test setting Figure 10 3 Ramping profile ...
Страница 129: ... 130 ...
Страница 131: ... 132 ...