9. ENGINEERING MODE
- 122 -
9.2 RF Test [MENU 2]
9.2.1 SAR test
This menu is to test the Specific Absorption Rate.
1) SAR test on : Phone continuously process TX only. Call-setup equipment is not required.
2) SAR test off : TX process off
9.3 MF mode [MENU 3]
This manufacturing mode is designed to do the baseband test automatically. Selecting this menu will
process the test automatically, and phone displays the previous menu after completing the test.
9.3.1 All auto test
LCD, Backlight, Vibrator, Buzzer, Key Pad, Mic&Speaker,
9.3.2 Backlight
LCD Backlight is on for about 1.5 seconds at the same time, then off.
9.3.3 Buzzer
This menu is to test the volume of Melody. It rings in the following sequence. Volume 1, Volume 2,
Volume 3, Volume 0 (mute), Volume 4, Volume 5.
9.3.4 Vibrator
Vibrator is on for about 1.5 seconds.
9.3.5 LCD
1) LCD
Main LCD screen resolution tests horizontally and vertically one by one and fills the screen.
2) SubLCD
Sub LCD screen resolution tests horizontally and vertically one by one and fills the screen.
9.3.6 Key pad
When a pop-up message shows ‘Press Any Key’, you may press any keys including side keys, but not
[Soft2 Key]. If the key is working properly, name of the key is displayed on the screen. Test will be
completed in 15 seconds automatically.
Содержание C3380
Страница 1: ...Service Manual Model C3380 Date November 2005 Issue 1 0 Service Manual C3380 ...
Страница 3: ... 4 ...
Страница 83: ...4 TROUBLE SHOOTING 84 4 11 KEY backlight Trouble Test Points Figure 4 22 ...
Страница 98: ...4 TROUBLE SHOOTING 99 Yes No Yes No Replace M201 Establish a call Replace U101 Software Re_download ...
Страница 109: ...Note 110 ...
Страница 116: ... 117 8 PCB LAYOUT ...
Страница 117: ... 118 8 PCB LAYOUT ...
Страница 125: ...10 STAND ALONE TEST 126 Figure 10 2 HW test setting Figure 10 3 Ramping profile ...
Страница 129: ... 130 ...
Страница 131: ... 132 ...