Installation Manual
31
Accessory Installation Guide
Remote Temperature Sensor
• After deciding where the remote temperature sensor is installed,
decide the location and height of the fixing screws.
(Interval between the screws : 60mm).
• After removing the control box cover of the indoor unit,
remove the room temperature sensor in
CN-ROOM
of the main PCB.
• Insert the connector of remote sensor wire into
CN-ROOM
.
• Using the DC line hole when connecting the wire to Indoor PCB.
• For using the two thermistor fuction, the remote sensor should be installed from the wired remote
controller as far as possible.
• Refer to damper remote sensor manual for detailed installation metheod.
Remote sensor
Connecting wire
CN-ROOM
Fixing screws
60mm