10
WIRING CONNECTION
ENGLISH
Electrical Wiring
Perform the electrical wiring work according
to the electrical wiring connection.
- All wiring must comply with local
requirements.
- Select a power source that is capable of
supplying the current required by the air
conditioner.
- Use a recognized ELCB(Electric Leakage
Circuit Breaker) between the power source
and the unit. A disconnection device to
adequately disconnect all supply lines must
be fitted.
- Model of circuit breaker recommended by
authorized personnel only
Free Joint Single Outdoor, Ceiling Cassette <Type : 4Way>,
Ceiling Suspended Air conditioner, Ceiling Concealed Duct,
Floor Standing Air Conditioner
Outdoor
Indoor
Main
power source
Switch box
ELCB
Chassis
Phase(Ø)
ELCB
UL2 : 18 kBtu/h
1
20A
U24A : 24 kBtu/h
1
25A
U4 : 36 kBtu/h
1
30A
U4 : 48 kBtu/h
1
40A
U3 : 54 kBtu/h
1
U5 : 54 kBtu/h
Ceiling Cassette <Type : Round>
Chassis
Phase(Ø)
ELCB
U4 : 36 kBtu/h
1
25A
U3 : 48, 50 kBtu/h
1
40A
WIRING CONNECTION