8
ENGLISH
THE INDOOR UNIT INSTALLATION
Level gauge
Ceiling
Ceiling board
CAUTION
• This air-conditioner uses a drain pump.
•
Install the unit horizontally using a level
gauge.
• During the installation, care should be
taken not to damage electric wires.
!
- Select and mark the position for fixing bolts
and piping hole.
- Decide the position for fixing bolts slightly
tilted to the drain direction after considering
the direction of drain hose.
- Drill the hole for anchor bolt on the wall.
NOTE
!
Avoid the following installation location.
1
Such places as restaurants and kitchen
where considerable amount of oil steam
and flour is generated. These may cause
heat exchange efficiency reduction, or
water drops, drain pump mal-function. In
these cases, take the following actions;
- Make sure that ventilation fan is enough
to cover all noxious gases from this
place.
- Ensure enough distance from the cook-
ing room to install the air conditioner in
such a place where it may not suck oily
steam.
2
Avoid installng air conditioner in such
places where cooking oil or iron powder is
generated.
3
Avoid places where inflammable gas is
generated.
4
Avoid places where noxious gas is gener-
ated.
5
Avoid places near high frequency genera-
tors.
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table
Air conditioner
Take enough
distance
THE INDOOR UNIT INSTALLATION
Unit:mm
875(Ceiling opening)
787(Hanging bolt)
6
8
4
(Hanging bolt)
67
1
8
75
(C
eiling opening)
840 Unit size
84
0 Unit si
ze
TP/TN/TM Series
Содержание ATNQ18GPLE7
Страница 18: ...1 MFL61971240 영영 2017 6 19 영영 1 54 Page 18 ...