Operation
Auto restarting operation
• When the power is restarted after a sudden power failure while in appliance operation, the mode before the
power failure is kept on the memory and the appliance automatically operates in the mode on the memory.
• Operation mode that is kept on the memory
- State of operation ON/OFF
- Operation mode/setting temp./selected airflow speed
- Sleep timer mode/remaining time of sleep timer
- Chaos Swing
• While in heating mode operation in order to protect the evaporator pipe of the outdoor unit from freezing,
reversed to cooling cycle to defrost the evaporator pipe of the outdoor unit.
• Defrosting control is available 50 minutes later since heating cycle started and the pipe temperature of out-
door unit reaches below -6°C.
Setting Freq.
Operating
Freq. of
Comp.
4-Way
EEV
Open step
Outdoor
FAN
Indoor
FAN
Pre-Heat
LED
Deice STEP
Fh
min
Minimum Time
of Heating
Main Deice time
Fh
min
Fh
min
ON
OFF
Setting
Speed
ON
Hot
Start
OFF
Hot
Starting
ON
OFF
OFF
0
1
2
3
4
5
6
Setting
Starting step
Setting
Freq.
Setting
Speed
Setting
Speed
Hi Speed
Defrosting control