-25-
• Wrap the area which accommodates the rear piping
housing section with vinyl tape.
• Bundle the piping and drain hose together by wrap-
ping them with vinyl tape for enough to cover where
they fit into the rear piping housing section.
3) Connection of the pipes-Outdoor
1. Align the center of the pipings and sufficiently
tighten the flare nut by hand.
2. Finally, tighten the flare nut with torque wrench
until the wrench clicks.
• When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the arrow on
the wrench.
Vinyl tape(narrow)
Connection
pipe
Connecting cable
Vinyl tape
(wide)
Wrap with vinyl tape
Indoor
unit pipe
Pipe
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
Outdoor unit
Liquid side piping
(Smaller diameter)
Torque wrench
Liquid side
piping
(Smaller
diameter)
GAS
LIQUID
Capacity
(Btu/h)
Refrigerant
7K, 8K, 9K
3/8"[4.2kg.m]
1/4"[1.8kg.m]
R-22
11K, 12K, 14K
1/2"[5.5kg.m]
1/4"[1.8kg.m]
7K~14K
3/8"[4.2kg.m]
1/4"[1.8kg.m]
R-410A
Pipe Size[Torque]
Содержание AS-H096PBC0