-47-
Fan couln't operate for dehumidifying mode.
- Change operation for cooling mode.
* Don't insert the connector wire at CN-Motor 1, 2 when its main power turn on.
Turn off Main power
Check the connection of CN-MOTOR1, 2
Check the Fan Motor (Motor resistance) (fig 1)
Check the Fuse(AC250V/3.15A)
Turn ON Main Power
- Check the soldering on AC PWB Assembly (6811A10096)/DC PWB (6871A10097).
- AC PWB Assembly : check the connection CN-AC/DC
,
and
,
- DC PWB Assembly : check the connection CN-AC/DC
,
and
,
4. When indoor Fan does not operate.
1
2
3
4 5
6
7
- If the Test result isn't the same
as the table, ti is motor
trouble.