5.12 Low Ambient control
• If outdoor temperature drops below certain temperature, liquid back is prevented by reducing fan speed.
• It can prevent frosting of evaporator and keep cooling operation
• No matter even if the outdoor temperature reaches -10°C.
• You can Cool your room at your desired temperature all your around.
5.13 Test Operation (Cooling)
• Press the Tact Switch for compulsory operation of the main body for 3 seconds in order to operate the unit in the trial
operation mode.
- Operation mode: Cold
- Indoor pan: Strong wind
- COMP frequency: Step 5
- COMP compulsorily operates for about 18 minutes irrespective of indoor temperature.
Freq.
- 0
°
C
°
…
Outdoor temp.
Outdoor pipe temp.
0
°
C outdoor fan On/Off
control
°
Comp Freq.
Outdoor fan
On
On
Off
Off
Outdoor temp.:-10
°
C
-5
0
5
10
15
20
25
0
50
100
150
200
Time(Min.)
Temp.(
°
C)
Outdoor fan On/Off control
Cond . temp.