Wall Mounted _
16
Indoor Units
LCS
(Light Commercial System) Indoor unit
10. Installation
■
Bundle the piping and drain hose together by wrap-
ping them with cloth tape over the range within
which they fit into the rear piping housing section.
8. Reroute the pipings and the drain hose across
the back of the chassis.
9. Set the pipings and the drain hose to the back
of the chassis with the tubing holder.
■
Hook the edge of tubing holder to tap on chassis
and push the bottom of tubing holder to be
engaged at the bottom of chassis.
10. Indoor unit installation
■
Remove the spacer.
■
Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
Drain hose
Vinyl tape
(narrow)
Pipe
Wrap with
vinyl tape(wide)
Drain hose
Connecting
Piping for
passage through
piping hole
Tubing holder
Hook
Push
2
1