background image

3

4

industry-accredited assessment authority regard of flammable
refrigerants, which authorizes their competence to handle re-
frigerants safely in accordance with an industry recognized as-
sessment specification.

• Servicing shall only be performed as recommended by the

equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel shall be carried out under
the supervision of the person competent in the use of flamma-
ble refrigerants.

• Keep any required ventilation openings clear of obstruction.
• Refrigerant tubing shall be protected or enclosed to avoid

damage.

• Flexible refrigerant connectors (such as connecting lines be-

tween the indoor and outdoor unit) that may be displaced dur-
ing normal operations shall be protected against mechanical
damage.

• Mechanical connections shall be accessible for maintenance

purposes.

• A brazed, welded, or mechanical connection shall be made be-

fore opening the valves to permit refrigerant to flow between
the refrigerating system parts.

• Use non-flammable gas (nitrogen) to check for leak and to

purge air.

• Use only refrigerant grade pipe specific for R32 refrigerant. Do

Not Use R22 products, which have lower pressure ratings and
can result in excessive pressure, explosion and injury. 

• Inert gas (oxygen free nitrogen) should be used when you

checking for leaks, cleaning or repairs of pipes etc. If you are
using combustible gases including oxygen, appliance may
have the risk of fires and explosions.

• Do not discharge the refrigerant into the atmosphere.
• If refrigerant leaks, ventilate the room.
• Always check for gas (refrigerant) leakage after installation or

repair of appliance.

• Be cautious not to get injured by the sharp edges while in-

stalling the appliance or taking it out of its packaging.

• Ensure that you carry by the chassis when you lift the unit.
• This appliance should only be transported by two or more peo-

ple holding the appliance securely.

• Safely dispose of packing materials such as screws, nails or

batteries using proper packaging after installation or repair.

• To avoid nitrogen entering the refrigerant system in a liquid

state, the top of the cylinder must be higher than its bottom
when you pressurize the system.

• The tubing shall be protected to the extent that it will not be

handled or used for carrying during moving of the appliance.

• Ventilation system have to be installed in the space when ap-

pliance with R32 is using for cooling of electric equipment.

• Do not use the appliance for special purposes, such as pre-

serving foods, works of art, and etc. It is an appliance for con-
sumer purposes, not a precision refrigerant system. There is
risk of damage or loss of property.

• Do not install the unit in potentially explosive atmospheres.

Refrigerant (for R32 Only)

WARNING

• The appliance shall be stored in a well-ventilated area where

the room size corresponds to the room area as specified for
operation.

!

• The appliance shall be stored in a room without continuously

operating open flames (for example an operating gas appli-
ance) and ignition sources (for example an operating electric
heater).

• The appliance shall be stored so as to prevent mechanical

damage from occurring.

• Do not use means to accelerate the defrosting process or to

clean, other than those recommended by the manufacturer.

• Do not pierce or burn.
• Be aware that refrigerants may not contain an odour.
• Pipe-work shall be protected from physical damage and shall

not be installed in an unventilated space, if that space is
smaller than the minimum floor area.

Minimum Floor Area

• m: Total refrigerant amount in the system
• Total refrigerant amount: Factory refrigerant  

Additional refrigerant amount

• Do not use copper pipes which are deformed. Otherwise, the

expansion valve or capillary tube may become blocked with
contaminants.

• Ducts connected to an appliance shall not contain an ignition

source. 

• The installation of pipe-work shall be kept to a minimum.
• When installing or relocating the appliance, consult with a quali-

fied technician to set up the appliance. The appliance should not
be installed by someone without proper qualifications.

• Operating the appliance while it is disconnected to the pipe

could result in explosion and damage. Use the appliance after
connecting it to the pipe once the appliance has been relo-
cated and the refrigerant circuit repaired.

• Do not place a heater or other heating appliances near the

power cable.

CAUTION

To reduce the risk of minor injury to persons, malfunction, or
damage to the product or property when using this product, fol-
low basic precautions, including the following:
• Install at places where it can endure the weight and

vibration/noise of the outdoor unit.

• Install the appliance in a place where the noise from the out-

door unit or the exhaust air will not inconvenience the neigh-
bors. Failure to do so may result in conflict with the neighbors.

• Ensure the appliance is installed level. Otherwise, it may

cause vibration or water leakage.

• Install the drain hose properly for the smooth drainage of

water condensation.

• Do not touch the leaking refrigerant during installation or re-

pair.

!

m (kg)

Minimum Floor Area (m

2

)

Floor Standing Wall Mounted Ceiling Mounted

< 1.224

-

-

-

1.224

12.90

1.43

0.956

1.2

12.36

1.37

0.92

1.4

16.82

1.87

1.25

1.6

21.97

2.44

1.63

1.8

27.80

3.09

2.07

2.0

34.32

3.81

2.55

2.2

41.53

4.61

3.09

2.4

49.42

5.49

3.68

Содержание AM07BP.NSJ

Страница 1: ...he appliance shall be installed in accordance with national wiring regulations Compliance with national gas regulations shall be observed Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules If the supply cord is damaged it must be replaced by the man ufacturer or its service agents or similarly qualified person in order to avoid a hazard Appliance s...

Страница 2: ...or con sumer purposes not a precision refrigerant system There is risk of damage or loss of property Do not install the unit in potentially explosive atmospheres Refrigerant for R32 Only WARNING The appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation The appliance shall be stored in a room without continuously operating op...

Страница 3: ... Spanner Torque wrench Multi meter Hexagonal wrench Ammeter Gas leak detector Thermometer Level Flaring tool set Name Select the best Location There should not be any heat or steam near the unit Select a place where there are no obstacles around of the unit Make sure that condensation drainage can be conveniently routed away Do not install near a doorway Ensure that the interval between a wall and...

Страница 4: ...rrs removal 1 Completely remove all burrs from the cut cross section of pipe tube 2 While removing burrs put the end of the copper tube pipe in a downward direction while removing burrs location is also changed in order to avoid dropping burrs into the tubing Putting nut on Remove flare nuts attached to indoor and outdoor unit then put them on pipe tube having completed burr removal not possible t...

Страница 5: ...es according to color codes referring to the wiring diagram NOTE The power cord connected to unit should be selected according to the following national wiring regulations The supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord code designation 60245 IEC 57 H05RN F CAUTION Outdoor unit 1 Remove the tubing cover from the unit by loose...

Страница 6: ...r 2 Connect a field supplied vinyl hose to the drain nipple A If the hose is too long and hangs down fix it carefully to prevent kinks The feature can be changed according to type of model Do not raise Water leakage Tip of drain hose dipped in water Water leakage Ditch Less than 50mm gap Accumulated drain water Air Waving Water leakage B A C 6 6 kW 2 5 3 5 5 0 kW Forming the Piping Form the piping...

Страница 7: ...3 Reattach the cover by pushing it back into position If you press and hold the On Off button for 3 5 seconds instead of 6 seconds the unit will switch to the test operation In the test operation the unit blows out strong air for cooling for 18 minutes and then returns to the factory default settings This is performed when the unit is relocated or the refrigerant circuit is serviced Pump Down mean...

Страница 8: ...lti model refer to Multi outdoor unit installation manual Capacity kW Pipe Size Standard Length m Max Length Ⓐ m Max Elevation Ⓑ m Additional Re frigerant g m GAS LIQUID mm inch mm inch 2 5 3 5 Ø9 52 3 8 Ø6 35 1 4 7 5 20 10 20 5 0 Ø12 7 1 2 Ø6 35 1 4 7 5 20 10 20 6 6 Ø15 88 5 8 Ø6 35 1 4 7 5 30 15 30 Capacity Mode Indoor temperature Outdoor temperature 2 5 3 5 kW Cooling 18 C 32 C 15 C 48 C Heatin...

Отзывы: