10. Performance data
50Hz, R410A _
29
Single Package
Single Package
10.2 Heating Capacity
10RT AK-H1208C02 (SI)
AFR(l/s)
DB(°C)
16.0
18.0
1397
20.0
22.0
24.0
16.0
18.0
1746
20.0
22.0
24.0
16.0
18.0
2095
20.0
22.0
24.0
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
20.8
9.2
24.5
10.0
28.4
10.9
29.8
11.2
31.3
11.6
20.2
9.5
23.8
10.4
27.5
11.3
28.9
11.6
30.3
12.0
19.6
9.8
23.1
10.7
26.7
11.7
28.0
12.0
29.4
12.4
18.9
10.1
22.2
11.0
25.7
12.0
27.0
12.4
28.3
12.8
18.2
10.4
21.5
11.4
24.8
12.4
26.1
12.8
27.3
13.2
21.2
8.4
24.9
9.2
28.9
10.0
30.3
10.3
31.8
10.6
20.5
8.7
24.2
9.5
27.9
10.3
29.4
10.6
30.8
11.0
19.9
9.0
23.4
9.8
27.1
10.7
28.5
11.0
29.8
11.3
19.2
9.2
22.6
10.1
26.1
11.0
27.4
11.3
28.8
11.7
18.5
9.5
21.8
10.4
25.2
11.3
26.5
11.7
27.8
12.0
21.6
8.0
25.5
8.7
29.4
9.5
30.9
9.8
32.4
10.1
20.9
8.3
24.6
9.0
28.5
9.8
29.9
10.2
31.4
10.5
20.3
8.5
23.9
9.3
27.7
10.2
29.1
10.5
30.4
10.8
19.6
8.8
23.0
9.6
26.7
10.5
28.0
10.8
29.3
11.1
18.9
9.1
22.3
9.9
25.7
10.8
27.0
11.2
28.3
11.5
TC
PI
TC
PI
TC
PI
33.0
11.8
35.7
12.4
39.5
13.3
32.0
12.2
34.6
12.8
38.2
13.7
30.8
12.6
33.6
13.2
37.1
14.2
29.9
13.0
32.4
13.7
35.7
14.6
28.9
13.4
31.3
14.1
34.5
15.1
33.6
10.8
36.3
11.3
40.1
12.2
32.5
11.1
35.2
11.7
38.8
12.6
31.3
11.5
34.1
12.1
37.7
13.0
30.4
11.9
32.9
12.5
36.3
13.4
29.4
12.2
31.8
12.9
35.1
13.8
34.2
10.3
37.1
10.8
40.9
11.6
33.2
10.6
35.9
11.2
39.6
12.0
32.0
11.0
34.8
11.6
38.4
12.4
31.0
11.3
33.6
11.9
37.0
12.8
29.9
11.7
32.4
12.3
35.8
13.2
Indoor
Outdoor WB(°F)
-10.0
-5.0
0
2.0
4.0
6.0
10.0
15.0
Notes:
1. All capacities are net, indoor fan motor heat is deducted.
2. Capacities are based on the following conditions.
Outdoor air : 85%RH. However, the condition on nominal
capacity is 7°CDB/6°CWB.
3. TC=Total Capacity(SI Unit : kW, English Unit : MBH = kBtu/h.
4. PI=Power Input(Comp.+indoor fan motor+outdoor fan motor) (kW).
5. Air Flow Rate(SI : l/s, English : CFM).
Correction Factor for Heating Capacity due to Frost on Heat Exchanger and Defrosting Operation.
The heating capacity in the "Heating Capacity Table" above indicates the actual heating capacity excluding the effect of frost on the heat
exchanger and the defrosting operation. Therefore, use the following factor to calculate the average heating capacity including capacity
reduction by frost on the exchanger and defrosting operation.
Correction Factor
Outdoor Air Temperature (°CWB, RH=85%)
Correction Factor
10
-6
-4
-2
0
2
4
6
0.95
0.95
0.89
0.87
0.87
0.89
0.91
1.00
10RT AK-H1208C02 (English)
AFR(CFM)
DB(°F)
60.8
64.4
2960
68.0
71.6
75.2
60.8
64.4
3700
68.0
71.6
75.2
60.8
64.4
4440
68.0
71.6
75.2
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
71.1
9.2
83.8
10.0
97.0
10.9
101.8
11.2
106.7
11.6
68.9
9.5
81.2
10.4
93.9
11.3
98.6
11.6
103.3
12.0
66.8
9.8
78.7
10.7
91.1
11.7
95.7
12.0
100.2
12.4
64.4
10.1
75.9
11.0
87.8
12.0
92.2
12.4
96.6
12.8
62.2
10.4
73.3
11.4
84.8
12.4
89.0
12.8
93.3
13.2
72.3
8.4
85.2
9.2
98.5
10.0
103.5
10.3
108.4
10.6
70.0
8.7
82.5
9.5
95.4
10.3
100.2
10.6
105.0
11.0
67.9
9.0
80.0
9.8
92.6
10.7
97.2
11.0
101.9
11.3
65.5
9.2
77.1
10.1
89.2
11.0
93.7
11.3
98.2
11.7
63.2
9.5
74.5
10.4
86.2
11.3
90.5
11.7
94.8
12.0
73.8
8.0
86.9
8.7
100.5
9.5
105.6
9.8
110.6
10.1
71.4
8.3
84.1
9.0
97.3
9.8
102.2
10.2
107.1
10.5
69.3
8.5
81.6
9.3
94.4
10.2
99.2
10.5
103.9
10.8
66.8
8.8
78.7
9.6
91.0
10.5
95.6
10.8
100.2
11.1
64.5
9.1
76.0
9.9
87.9
10.8
92.3
11.2
96.7
11.5
TC
PI
TC
PI
TC
PI
112.7
11.8
122.0
12.4
134.7
13.3
109.2
12.2
118.2
12.8
130.4
13.7
105.3
12.6
114.7
13.2
126.6
14.2
102.1
13.0
110.5
13.7
122.0
14.6
98.6
13.4
106.7
14.1
117.8
15.1
114.6
10.8
124.0
11.3
136.9
12.2
111.0
11.1
120.1
11.7
132.6
12.6
107.0
11.5
116.5
12.1
128.6
13.0
103.8
11.9
112.3
12.5
124.0
13.4
100.2
12.2
108.5
12.9
119.7
13.8
116.9
10.3
126.5
10.8
139.7
11.6
113.2
10.6
122.5
11.2
135.2
12.0
109.2
11.0
118.9
11.6
131.2
12.4
105.9
11.3
114.6
11.9
126.5
12.8
102.2
11.7
110.7
12.3
122.1
13.2
Indoor
Outdoor WB(°F)
14.0
23.0
32.0
35.6
39.2
42.8
50.0
59.0