Accessories Installation
A
E
C
A
B
C D
A
E
A
D
Relay contactor
port no. assignment
ELB(MCCB) port no.
assignment
0
1
2
6
4
8
1
3
2
4
How to Install Sanitary Water Tank Kit
Follow below procedures Step 1 ~ Step 6.
Step 1.
Find a relay contactor and ELB(MCCB) in the kit. Bolt
them into control box. (symbol
Ⓐ
at picture)
Step 2.
Connect ʻCN_B/HEAT(A)ʼ (White Connector) of the
indoor unit PCB with relay contact using included cable
(symbol
Ⓑ
at the picture). Connect relay contactor port
no. 0 and 1.
Step 3.
Connect relay contactor port no. 2 and 6 with
ELB(MCCB) port no. 2 and 4. (symbol
Ⓒ
at the
picture).
Check Polarity
• Connect relay contact port no. 2 to ELB(MCCB) port no. 2
• Connect relay contact port no. 6 to ELB(MCCB) port no. 4
Step 4.
Connect relay contactor port no. 4 and 8 with terminal
block 1 port 6 and 7. (symbol
Ⓓ
at the picture).
Check Polarity
• Connect relay contact port no. 4 to terminal block 1 port 6
• Connect relay contact port no. 8 to terminal block 1 port 7
Step 5.
1Ø Electric Heater
’
Connect ELB(MCCB) port no. 1 and 3 with terminal
block 3 port 3 and 4. (symbol
Ⓔ
at the picture).
3Ø Electric Heater
’
Connect ELB(MCCB) port no. 1 and 3 with terminal
block 3 port 1 and 2. (symbol
Ⓔ
at the picture).
Check Polarity
1Ø Electric Heater
• Connect ELB(MCCB) port no. 1 to terminal block 3 port 3
• Connect ELB(MCCB) port no. 3 to terminal block 3 port 4
3Ø Electric Heater
• Connect ELB(MCCB) port no. 1 to terminal block 3 port 1
• Connect ELB(MCCB) port no. 3 to terminal block 3 port 2
Note
:
Some models are using MCCB instead of ELB
1Ø Electric Heater
3Ø Electric Heater