4. Trouble Shooting
Cause of
Trouble
Condition
Mechanism of Fault Generation
Generation
of refrigerant
flow distur-
bance
Bending/Blocking of a pipe
EEV fault Closing of SVC Valve
Freezing of indoor device
⳨
Reduced evaporation temperature due to
excessive expansion of refrigerant.
Weak heating and cooling
⳨
Insufficient flow of refrigerant
Frequent turning on/off of the compressor by
the high/low pressure protection logic
⳨
Accumulated refrigerant elevates the tem-
perature and reduces the pressure.
Wrong oil collection elevates the outlet tem-
perature of the compressor and damages the
compressor.
Bending/Blocking of a pipe
Checking SVC Valve
Bending of a pipe
OPEN
Check pipes
SVC Valve
Check
EEV Check
Replacing a part of or
the entire pipes
SVC Valve Full Open
Replacing EEV
Ⲽ&&7$IFDLJOH.FUIPE
$IFDLUIFPQFOJOHDMPTJOH
TPVOEPG&&7XIFOUIFQPXFS
JTBQQMJFEGPSUIFGJSTUUJNF
(FOFSBUJPOPGSFGSJHFSBOUGMPXEJTUVSCBODF
6.7 Troubleshooting Outdoor Error
CH 21 (DC Peak / Comp IPM Fault)