4.1 E.S.P. (External Static Pressure) Setting
4. Installation Functions
Function Code
Pressure
Press button for 4 seconds to enter the installer
setting mode until timer segment displays “01:01”.
1
Select static pressure by pressing button.
(01:V-H, 02:F-H, 03:V-L, 04:F-L)
3
Press button to save.
4
5
Pressing button will exit settings mode.
❈
After setup, it automatically gets out of setup mode if there is no button
input for 25 seconds.
❈
When exiting without pressing set button, the manipulated value is not
reflected.
If pressing button repeatedly, it moves to static pressure
selection menu as picture below.
2
This function is applied to only duct type. Setting this in other cases will cause malfunction.
<Static Pressure Setting Table>
Part 2 Functions & Controls
Pressure selection
Function
Zone state
ESP standard value
01
V-H
Variable
High
02
F-H
Fixed
High
03
V-L
Variable
Low
04
F-L
Fixed
Low