Indoor Unit
- Open the control box cover and connect the Remote controller cord and Indoor power wires.
- Remove the control box cover for electrical connection between the indoor and outdoor unit.
(Remove screws
①
.)
- Use the cord clamper to fix the cord.
CAUTION
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 1.0mm
2
The connecting cable
connected to the indoor and outdoor unit should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer of its
service agent. When the connection line between the indoor unit and outdooor unit and outdoor unit is over 40m, connect
the telecommunication line and power line separately.
1
Control box cover
(On which the Electric
Wiring Connection is put)
Control box
Control terminal board
Remote controler cord
Connection cord between the indoor
unit and the outdoor unit