10
INSTALLATION PLACE
ENGLISH
Select space for installing outdoor unit, which
will meet the following conditions:
- No direct thermal radiation from other heat
sources
- No possibility of annoying neighbors by noise
from unit
- No exposition to strong wind
- With strength which bears weight of unit
- Note that drain flows out of unit when heat-
ing
- With space for air passage and service work
shown next
- Because of the possibility of fire, do not
install unit to the space where generation,
inflow, stagnation, and
leakage of combustible gas is expected.
- Avoid unit installation in a place where acidic
solution and spray (sulfur) are often used.
- Do not use unit under any special environ-
ment where oil, steam and sulfuric gas exist.
- It is recommended to fence round the out-
door unit in order to prevent any person or
animal from accessing the outdoor unit.
- If installation site is area of heavy snowfall,
then the following directions should be
observed.
• Make the foundation as high as possible.
• Fit a snow protection hood.
- Select installation location considering fol-
lowing conditions to avoid bad condition
when additionally performing defrost opera-
tion.
• Install the outdoor unit at a place well venti-
lated and having a lot of sunshine in case
of installing the product at a place With a
high humidity in winter (near beach, coast,
lake, etc. )
(Ex : Rooftop where there is always sun-
shine.)
INSTALLATION PLACE
Содержание 62AWYU7L6