66
Plasma Display Panel Troubleshooting - 2007
Input Voltages from the Y SUS Board
VS
VS is supplied to IC7 and the SUS_IPM through coil FL5 and to the primary winding of
transformer T3 to the Z Bias Circuit. Input voltage measurement is made from connector
P12 pins 11 and 12, to chassis ground.
VA
VA is supplied to the ER_HIGH IPM through resistor R10 and diode D18. VA voltage is also
routed to connectors P1 pin 5 and P9 pin 5 for the right top and bottom X driver boards.
5v
5v is used to Bias the circuits on the Z_ SUS Board. 5v also feeds connectors P1 pin 3 and P9
pin 3 for the right top and bottom X boards.
Voltages Developed on the Z SUS Board
Z Bias
165v is used to Bias the output circuits driving the Sustain and Erase Pulses, removing previous images
from the PDP. Z-bias is measured from the Vzb TP on the Z SUS Board and adjusted by VR3
IPM 18v
IPM 18V needed to generate the Sustain and Erase pulses in the IPMs. Measured at positive side of Capacitor
C18 ( Located between the IPMs IC7 and IC3 ).
Troubleshooting
60PC1D Z SUS Board
Содержание 60PC1D - - 60" Plasma TV
Страница 15: ...15 Plasma Display Panel Troubleshooting 2007 Input Jacks Troubleshooting 60PC1D Circuit Board Layout ...
Страница 30: ...30 Plasma Display Panel Troubleshooting 2007 C241 C242 C240 C244 On Off From Micro ...
Страница 121: ...121 Plasma Display Panel Troubleshooting 2007 Troubleshooting LG Power Supplies Troubleshooting ...
Страница 130: ...130 Plasma Display Panel Troubleshooting 2007 The End Thank You Troubleshooting Collection By Pravin Mevada ...