81
Plasma Display Panel Troubleshooting - 2007
LVDS Connector
Remove LVDS Cable
and short pins 1 and
2 of connector P4 to
display test patterns.
If patterns are not
present, Control
board is defective
LVDS
poor connection
Defect display
Regular vertical
lines
CONTROL IC
No picture
Oscilator
No display or
Partly no display
Connector
Part
Description of
defect
Defect part
▶
Main Defect : MCM , connector, oscilator, LVDS poor connection
▶
Voltage used : 3.3V/3.3V/3.3V/2.4V/1.8V(5 separate operating voltages).
< MCM >
< Connector >
< Oscillator >
< Partly no display >
< Poor connection >
60PC1D Control Board
< Display Lines >
Replace
Control
Board
Reseat
Control
Board
Connectors
Replace
Control
Board
Reconnect
LVDS or
Replace
Control Board
Solution
Troubleshooting