Established
date
Standard Repair Process Detail Technical Manual
Revised
date
A10
Error
symptom
Content
Check power input voltage and ST-BY 7.8V
B. Power error _No power
SET Model
Power P/N, Name
50UL3G
EAY65769221 , LGP50T-20U1
MS Level
Range [V]
LED On/Off
MS (0V)
0 ~ 0.25
Off
MS (2V)
1.75 ~ 2.25
On (Home mode)
MS (3V)
2.75 ~ 3.25
On (Store Mode)
Power Check Sequence
1. AC input Check : SK100 (100~240Vac)
2. PWR-ON Check : J3
- SET On : above 3V
- SET St-by : 0V
3. 13.2V DC Check : D201 center Pin
- SET On : 13.2V
- SET St-by : 7.8V
4. MS Level Check : MS Check Hole
5. LED voltage Check : P801, Pin 1-7
※
Home mode : General Customer
Store mode : use Store
all condition meets, Power Board OK.
SK100 (AC input)
Power Board Voltage / Current
D201 (13.2V)
- Center Pin
P801
P201
Picture Condition : VIVID (Back light 100)
Min
Typ.
Max
152.1 V
169 V
185.9 V
A10
MS
J3- PWR-ON
Copyright
ⓒ
2020 LG Electronics Inc. All rights reserved.
Only training and service purposes.
Содержание 50UL3G