Power Check Sequence
1. AC input Check : SK101 (100~240Vac)
2. PWR-ON Check : J18
- SET On : above 3V
- SET St-by : 0V
3. 13.2V DC Check : J3
- SET On : 13.2V [12.45V ~ 13.86V]
- SET St-by : 7.8V
4. MS Level Check : MS
5. LED voltage Check : P801, Pin 1-3,5-7
P801
Established
date
Standard Repair Process Detail Technical Manual
Revised
date
A14
Error
symptom
Content
Check power input voltage and ST-BY 7.8V
B. Power error _No power
MS Level
Range [V]
LED On/Off
MS (0V)
0 ~ 0.25
Off
MS (2V)
1.75 ~ 2.25
On (Home mode)
MS (3V)
2.75 ~ 3.25
On (Store Mode)
※
Home mode : General Customer
Store mode : use Store
Picture Condition : VIVID (Back light 100)
Voltage
Current (MS2)
240 V
410mA(393~434.8mA)
240 V
410mA(393~434.8mA)
SK100 (AC input)
Power Board Voltage / Current
P201
all condition meets, Power Board OK.
SET Model
Power P/N, Name
86UL3G
EAY64888601, LGP86TJ-18U1