5. Total Assembly line process
5.1. Adjustment Preparation
▪ W/B Equipment condition
CA210: LED
→
CH14, Test signal: Inner pattern(80IRE)
▪ Above 5 minutes H/run in the inner pattern. ("power on" key
of Adjustment remote control)
* The spec of color temperature and coordinate.
5.1.1. W/B adj. Objective & How-it-works
(1) Objective: To reduce each Panel’s W/B deviation
(2) How-it-works: When R/G/B gain in the OSD is at 192, it
means the panel is at its Full Dynamic Range.
In order to prevent saturation of Full Dynamic range and
data, one of R/G/B is fixed at 192, and the other two is
lowered to find the desired value.
(3) Adj. condition: normal temperature
- Surrounding Temperature: 25 ± 5 °C
- Warm-up time: About 5 Min
- Surrounding Humidity: 20% ~ 80%
- Before White balance adjustment, Keep power on status,
don’t power off
* If Model is POLA model
* W/B Table( Netcast4.0 Model)
CA210 : CH 14, Test signal : Inner pattern (80IRE)
Normal line - Standard color coordinate and temprature using
CA-1000(by H/R time)
Aging chamber line - Standard color coordinate and temprature
using CA-1000(by H/R time)
* When Model produce in Gumi Factory at Winter(Jan,Feb)
Normal line
* AUO, Sharp, CSOT use Model(If Cool spec 13000K)
Mode
Color Temp
Color coordinate
Remark
Cool (C50)
13,000 K
X=0.271 (±0.002)
Y=0.270 (±0.002)
<Test Signal>
- Inner pattern
for W/B adjust
- External white
pattern(80IRE,
204gray)
Medium(0)
9,300 K
X=0.286 (±0.002)
Y=0.289 (±0.002)
Warm(W50)
6,500 K
X=0.313 (±0.002)
Y=0.329 (±0.002)
NC4.0
Aging
time
(Min)
Cool
Medium
Warm
x
y
x
y
x
y
271
270
286
289
313
329
1
0-2
282
289
297
308
324
348
2
3-5
281
287
296
306
323
346
3
6-9
279
284
294
303
321
343
4
10-19
277
280
292
299
319
339
5
20-35
275
277
290
296
317
336
6
36-49
274
274
289
293
316
333
7
50-79
273
272
288
291
315
331
8
80-119
272
271
287
290
314
330
9
Over 120
271
270
286
289
313
329
NC4.0
Aging
time
(Min)
Cool
Medium
Warm
x
y
x
y
x
y
271
270
285
293
313
329
1
0-5
280
285
294
308
319
340
2
6-10
276
280
290
303
315
335
3
11-20
272
275
286
298
311
330
4
21-30
269
272
283
295
308
327
5
31-40
267
268
281
291
306
323
6
41-50
266
265
280
288
305
320
7
51-80
265
263
279
286
304
318
8
81-119
264
261
278
284
303
316
9
Over 120
264
260
278
283
303
315
NC4.0
Aging
time
(Min)
Cool
Medium
Warm
x
y
x
y
x
y
271
270
286
289
313
329
1
0-5
286
295
301
314
328
354
2
6-10
284
290
299
309
326
349
3
11-20
282
287
297
306
324
346
4
21-30
279
283
294
302
321
342
5
31-40
276
278
291
297
318
337
6
41-50
274
275
289
294
316
334
7
51-80
273
272
288
291
315
331
8
81-119
272
271
287
290
314
330
9
Over 120
271
270
286
289
313
329
NC4.0
Cool
Medium
Warm
x
y
x
y
x
y
spec
271
270
286
289
313
329
target
278
280
293
299
320
339
Case : Cool Mode
•
Purpose : Adjust the color temperature to reduce the
deviation of the module color temperature.
•
Principle : To adjust the white balance without the
saturation, Fix the G gain to 172 (default data) and
change the others ( R/B Gain ).
•
Adjustment mode : mode - Cool
Case : Medium / Warm Mode
•
Purpose : Adjust the color temperature to reduce the
deviation of the module color temperature.
•
Principle : To adjust the white balance without the
saturation, Fix the one of R/G/B gain to 192 (default
data) and decrease the others.
•
Adjustment mode : Two modes - Medium / Warm
Содержание 47LB5610