![LG 42V5 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/lg/42v5/42v5_instruction-manual_217617030.webp)
30
/39
◎
Checking address COF input of resistor and IC
▶
COF resistor checking
Check the both side of resistor With Digital multi meter(DMM) .
If the resistor is normal, the resistor value will be 10.2 ~ 10.8
Ω
But if not, the value will be 0 or infinity and replace the resistor.
4. Trouble shooting.
Resistor
▶
COF short circuit check
Check the short circuit between Va and GND short.
If it is short, cof is failed.
Va
GND