6-6. Check the Baud Rate & RS-232C cable
•
when you connect the signage to the control system with RS-232C cable, you have to
check that the RS-232C cable is a crossed type, and the baud rate of control system &
signage is 9600
Signage
[ Signage ]
[ Controller System ]
(1) Check RS-232C Cable type : LGE use crossed type cable. (#2~#3, #3~#2)
(2) Check the Baud rate in your controller and Signage
1) In controller system
- Baud Rate : 9600
- Date Length : 8 bit
- Parity Bit : None
- Stop Bit : 1bit
2) In signage
- Baud Rate : 9600
RS-232C cable
69
RS-232C Configurations