D. Appendix 2 : Troubleshooting
54
Calibration pop up message
Resolution
Set to the maximum luminance
Reduce the target luminance level to a proper range.
Set ISM mode to normal.
Set to the minimum luminance
Increase the target luminance level to a proper range.
Fail to adjust color temperature
Please manually adjust Gain Value
Adjust manually.
Fail to change backlight
Set both Energy saving and Easy Brightness of Picture
menu to off.
Fail to change the mode
Check the control connection such as RJ45, RS232.
Fail to set RGB Gain/offset
Adjust manually.
Check the control connection such as RJ45, RS232.
Fail to find sensor error
Make sure your sensor is connected well to the unit being
calibrated.
Problem
Resolution
Did Calibration fail?
Refer to the Version Matching chart.
And If needed update both SOC(Flash) and Micom to the
latest version.
Is there any abnormal working at
SSC or monitor?
(e.g : R/G/B gains are over 192 after
calibration or SSC is hang-up or
terminated abnormally and so on.)
Check “Create Gamma Table” and calibrate again.
If the result is same, please adjust manually.
Note) If you set color temperature as over 11000,
“Create Gamma Table” should be checked for stable
working.
Is the white color different between
video wall screens after calibration?
More than 2 screens may have individual color and
brightness uniformity, this lack of uniformity could make
them to look different.
So proceed the manual adjustment white balance more
correctly.
There is color mismatching after
calibration.
Did you use Duplication function?
There could be problem when you use Duplication function
because of the uniformity of panel.
If you used Duplication function to reduce processing time,
we’d like to recommend doing calibration without “Create
Gamma Table”.
Содержание 26TS30MF
Страница 1: ... Openframe Media Player Transparent Video Wall Other Models Accessories MONITOR SIGNAGE MODELS V3 2 ...
Страница 18: ...3 4 How to connect the cable assembly Cable assembly 18 ...
Страница 60: ...5 4 Dimensions of 84WS70MS Refer to below the dimension of 84WS70MS 60 ...
Страница 93: ...93 ...