-56-
Check the TRIAC high speed operation by remote control.
(The Indoor Fan Motor is connected)
Turn off Main power
Check the connection of CN-MOTOR
Check the Fan Motor
Check the Fuse(AC250V/T2A)
Turn ON Main Power
Check the related circuit of indoor Fan Motor.
• The pin NO 63 of Micom, and the part for driving TRIAC(the input and
output signal of IC01M, PIN NO 2, 15)
• Check the pattern
• Check the TRIAC
- TRIAC Open: Indoor Fan Motor never operate
- TRIAC short: Indoor Fan Motor always operates in case of ON or OFF.
4. When indoor Fan does not operate.
The voltage of PIN NO 1(blue) and 3(yellow) of CN-MOTOR.
About AC 180V over
About AC 50V over
TRIAC is not damaged
TRIAC Check
Содержание -
Страница 60: ... 60 Electronic Control Device 1 MAIN P W B ASSEMBLY 2 MAIN P W B ASSEMBLY ...
Страница 61: ... 61 3 DISPLAY ASSEMBLY ...
Страница 62: ...Schematic Diagram 62 Heat Pump Series ...
Страница 80: ...P No 3828A30033B January 2002 Printed in Korea ...