ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Net Feature Code
Networking Feature Code programming for Networking
paging call.
16 digits
None
Net Feature Destination
INT PAGE ZONE : 1-10
ALL CALL PAGE ZONE : INT(1), ALL(3)
3 digits
N/A
3.1.3.11 LCR Control Attribute
Selecting LCR Control Attributes will display the LCR Control Attributes data entry page.
The LCR Tables provide a mechanism to define the database, which will route outgoing calls,
particularly long distance, using the most cost effective route. User dialed digits are compared to
table entries and modified appropriately based on time of day, day of week, and assigned routes.
There are four LCR Tables, LCR Control Attributes, LCR Leading Digit Table, LCR Digit
Modification Table, and LCR Initialization Table.
The LCR Control Attributes Table, among other items, allows assignment of the LCR Access
Modes. The LCR Access Modes defines the user operations that will access the LCR feature. The
LCR Access Modes are:
LCR Disabled.
Loop (user dials ‘9’ or CO Group code (8xx), or presses a Loop button).
Loop and Internal (user dials digits without a CO Access Code prefix).
Loop and Direct CO Line (user dials CO Line Access Code (88xx) or pressing a {CO line}
button).
Loop, Direct CO Line, and Internal.
Loop, Direct CO Line, and Internal and Direct Loop.
In addition, days of the week are grouped into zones (Day Zones) and the time of day can be set
into three groups (Time Zones). Table 3.1.3.11 provides general descriptive information and input
ranges.
Table 3.1.3.11 LCR Assignment
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
LCR Access Mode
This entry defines the effective LCR modes, the modes by
which the user can access LCR.
Day Zone
Each day of the week is assigned to a Day Zone (1~3).
The active Day Zone is the Zone assigned to the current
day of the week.
days of the
week
Time Zone1
This entry defines the hours of the day during which Time
Zone 1 is active. Note hours not defined in Time Zone 2
and 3 are automatically part of Time Zone 1.
00~24
00~24
Time Zone2
This entry defines the hours of the day during which Time
Zone 2 is active.
00~24
Time Zone3
This entry defines the hours of the day during which Time
Zone 3 is active.
00~24
3.1.3.12 LCR LDT (Leading Digit Table)
Selecting LCR-LDT (Leading Digit Table) will display the LCR-LDT data entry page.
The Leading Digits Table is used to analyze the user-dialed digits to determine an appropriate Digit
Modification Table Index. The Table is divided into bins. The digits (up to the first 12) dialed by the