iPECS-MG Hardware Description and Installation Manual
Issue 1.1
DECT INSTALLATION
August, 2010
71
6.1.1 Terminal Cabling Distance
Figure 6.1.1-1 Terminal Cabling Distance
6.1.2 Terminal Connections
6.1.2.1 DKT Wiring
The Digital Key Telephone and digital DSS Console are terminated to the 1
st
pair of the RJ11 located
in the bottom of the DKT or Console. The wall outlet for the DKT or Console should be connected
back to an appropriate DTIB or MPB DSIU DKT port.
Referring to the pin-out chart below and Figure 6.1.1-1,
wire the wall outlet 1
st
pair to the DTIB or DSIU termination point using UTP cable. Note separate
wiring is required for the LDP-7048 DSS Console.
using the line cord provided, connect the DKT or DSS Console to the wall outlet.
DKT Pin-out Chart
Line Cord
CONNECTOR
PIN
SIGNAL NAME
1,2 Not
used
3 Ring
4 Tip
RJ11
5,6 Not
used
6.1.2.2 SLT wiring
SLTs are wired to the center pair of the RJ11, typically on the bottom or back of the SLT. The wall
outlet should be connected back to an appropriate SLIB or DSIU SLT port.
Referring to the pin-out chart below and Figure 6.1.1-1,