background image

Operating Instructions

14

Room Air Conditioner

or

or

o

During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely
high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used
to cool the room temp. in the shortest time in a hot summer.

In heat pump mode or neuro fuzzy mode, however, the JET COOL function is not available.

o

In order to return to the normal cooling mode from the JET COOL mode, you just press
either the operation mode selection button, airflow volume selection or temp. setting button
or the JET COOL button again.

NOTICE

Press the Start/Stop button.
The unit will respond with
a beep.

Press the

Jet Cool

button to operate

the speed cooling mode and the unit
will operate in super high fan speed
on cooling mode for 30 minutes.

To cancel the

Jet Cool

mode, press the

Jet Cool

button or

the fan speed button or the room temperature setting button
again and the unit will operate in high fan speed on cooling
mode.

1

2

3

Jet Cool Operation

For this operation 

P

0

 appears on the

display. (Plasma model only)

Содержание LG-BKE 6450 D

Страница 1: ...e retain this owner s manual for future reference after reading it thoroughly RoomAirConditioner OWNER S MANUAL Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 6055 3 Norm Models LG BKE 6450 D LG BKE 6500 D LG BKE 6600 D LG BKE 6700 D LG BKE 6800 D ...

Страница 2: ...eshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner When...

Страница 3: ...g properly Do not damage or use an unspecified power cord Otherwise it will cause electric shock or fire due to heat generation or electric shock It will cause electric shock or fire In the supply cord is damaged it mut be replaced by the manufacturer or its service agent or a similarly quallfied person in order to avoid a hazard Y Attachment Do not modify power cord length or share the outlet wit...

Страница 4: ...ion It may cause fire and electric shock accident It may cause electric shock Do not use the power cord close to the heating tools Do not use the power cord near flammable gas or combustibles such as gasoline benzene thinner etc It may cause fire and electric shock It may cause an explosion or fire Ventilate before operating air conditioner when gas goes out Do not disassemble or modify products r...

Страница 5: ...y the head of the power plug when taking it out Operation with windows opened may cause wetting of indoor and soaking of household furniture It may cause electric shock and damage Turn off the main power switch when not using it for a long time Do not place obstacles around the absorption inlet or instead of blowing out inlet It may cause failure of product or fire It may cause failure of applianc...

Страница 6: ...reserving precision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the p...

Страница 7: ... Receives the signals from the remote control Signal receiving sound two short beeps or one long beep Operation Indication Lamps On Off Lights up during the system operation Sleep Mode Lights up during Sleep Mode Auto operation Timer Lights up during Timer operation Defrost Mode Lights up during Defrost Mode or Hot Start operation Heat pump model only Lights up during outdoor unit operation Coolin...

Страница 8: ...t the desired up down airflow direction ON OFF TIMER BUTTONS OPTIONAL Used to set the time of starting and stopping operation See page 17 TIME SETTING BUTTONS Used to adjust the time See page 17 TIMER SET CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation See page 17 SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation See page 17 AIR CI...

Страница 9: ... the door on the remote control Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C in 1 C increments Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shifted 1 2 3 4 Natural wind by the CHAOS logic...

Страница 10: ...oom Temperature Setting buttons The cooler or warmer you feel the more times up to two times you should press the button The set temperature will be changed automatically During Auto Operation o You cannot switch the indoor fan speed It has already been set by the Fuzzy rule o If the system is not operating as desired manually switch to another mode The system will not automatically switch from th...

Страница 11: ...n The air conditioner changes the operation mode automatically to keep indoor temperature When room temperature vary over 2 C with respect to setting temperature air conditioner keeps the room temperature in 2 C with respect to setting temperature by auto changeover mode 1 2 Close the door on the remote control Set the temperature lower than the room temperature The temperature can be set within a...

Страница 12: ... room temp In this case however the setting temp is not displayed in the remote control and you are not able to control the room temp either During the healthy dehumidification function the airflow volume is automatically set according to the optimization algorithm responding to the current room temp status which makes the room condition healthy and comfortable even in the high humidity season 1 2...

Страница 13: ...n the remote control Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in 1 C increments Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shifted 1 2 3 4 Natural wind by the CHAOS logic o For mor...

Страница 14: ...m the JET COOL mode you just press either the operation mode selection button airflow volume selection or temp setting button or the JET COOL button again NOTICE Press the Start Stop button The unit will respond with a beep Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes To cancel the Jet Cool mode press t...

Страница 15: ...losed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Z Air purifying operation PLASMA can be with cooling Heating or any other operations PLASMA Air Purifying Operation only If you press the only PLASMA button only PLASMA air purifying operates Then fan speed is low You can select the fan speed in four steps low med...

Страница 16: ... remote control and press the 2nd Function button to operate functions printed in blue at bottom of buttons Check the indication of 2nd function on remote control display These buttons operate the timer setting as follows 2nd function goes off in a short time automatically or when the button is pressed again For more details refer to functions next page 1 2 3 2nd F Operation ...

Страница 17: ...t air conditioner Make sure the Sleep Mode Auto LED lights up To cancel the Sleep Mode press the sleep Mode Auto button several times until the star disappears from the operation display sleeping Time can be set only when you have pressed the Reset button If you have just replaced the batteries the Reset button should be pressed to reset the time Press the Start Stop button Press 2nd F button and ...

Страница 18: ... by hand NOTICE Vertical Airflow Direction Control Auto Clean Whenever you press the Auto Clean button Auto Clean Function will be reserved and cancelled Auto Clean function works before and after cooling or dehumidification mode For details refer to the below points When the unit is started after the reservation of Auto Clean the Cool Start function operates and indoor Fan is started after 20 sec...

Страница 19: ... cooling mode at high speed fan regardless of room temperature and resets in 18 minutes During test operation if remote controller signal is received the unit operates as remote controller sets If you want to use this operation open the front panel upward and Press the power button let it be pressed for about 3 seconds If you want to stop the operation re press the button For this operation L0 app...

Страница 20: ... remove the filter Clean the filter with a vacuum cleaner or warm soapy water If dirt is conspicuous wash with a solution of detergent in lukewarm water If hot water 40 C or more is used it may be deformed After washing with water dry well in the shade Re install the air filter NOTICE Vertical louver Horizontal louver Air filters behind front panel Air outlet vent Air inlet vent Gasoline Powder 1 ...

Страница 21: ...rt or soot the heat exchanger and panel vents may be professionally steam cleaned Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs NOTICE Replacement of Purifying Filter Optional Recomended use period About 2 years Open front panel and remove air filters Reinsert air filters and close front panel Remove Triple deodorizing Filters Insert new...

Страница 22: ...or outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Clean the air filter regularly Blocka...

Страница 23: ...e walls carpet furniture or cloth items in the room Condensation occurs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents obstructed For a noise ...

Отзывы: