41
Lower Tracking
The Lower Tracking (the Fill Cam, Ejection Cam, and Dosing Cam) guides the Lower Punches'
movement throughout the machine's operation.
To watch a video of what worn Lower Tracking cams look like on a similar machine, go to
www.lfatabletpresses.com/rtp-9-inspecting-lower-cams
Tools and Materials Needed
• Set of metric Allen keys with ball ends
• Crosshead screwdriver
• New Lower Tracking cams
• Disposable latex/rubber gloves (for food grade products and to protect hands from grease)
• Hairnet and/or beard net (food grade products only)
• Sterile shoe covers (food grade products only)
WARNING:
To prevent any potential personal injury, ALWAYS unplug the RTP
41
®
from the electrical outlet when replacing parts.
Instructions
Note: Wear latex/rubber gloves (and appropriate food grade attire if applicable) during this process.
Remove the Lower Tracking
1. Raise each Perspex door until they are held up by the pistons.
2. Remove the coverings below the Perspex doors with a crosshead screwdriver.