38
3. Loosen both of the Fill Trays' Thumb Bolts with an Allen key.
4. Remove both Fill Trays from the Turret.
5. Loosen both Fill Trays' Scrapers and Take-Off Blades' screws with a crosshead screwdriver.
6. Remove both Fill Trays' Scrapers and Take-Off Blades.
Replace the Take-Off Blades and Fill Trays Scrapers
7. Loosely secure the new Take-Off Blades and Scrapers on both Fill Trays with a crosshead
screwdriver.
8. Place the Fill Trays with the new Take-Off Blades and Scrapers onto the Turret.
9. Tighten the Fill Trays' Thumb Bolts and secure with an Allen key.
10. Tighten the Fill Trays' Scrapers and Take-Off Blades with a crosshead screwdriver.
10.1 Note: It is important to make sure that the Fill Trays' Scraper Blades are firmly up
against the Die Table of the Turret. To do this, push down on the top of the blades
while tightening the screws that hold it in place. The Take-Off Blades needs to not be
touching the Die Table and should be mounted approximately 1/3 of the height of the tablet
from the surface of the Die Table.
11. Lower each Perspex Door.
12. Reinsert the Hoppers into the top of the machine.