Replace the tip seals

Replace the tip seal as described below. Prepare the pump by running on 
gas ballast control for one hour to remove any process gases.

1.  Switch off the pump and isolate from the electrical supply.

2.  Using a 4 mm Allen key, undo the two screws (Figure 1, item 1) which 

secure the fan cowl and remove.

3.  Disconnect the motor fan lead from the controller (figure 2, item 1).

Figure 2 - Motor fan lead connector

1

Figure 1 - Fan cowl removal

1

Содержание SCROLLVAC plus

Страница 1: ...lacement Operating Instructions 300680362_002_C0 Spare Part Kit Numbers EK117141000 Minor Service Kit SC 7 15 EK117141001 Minor Service Kit SC 18 EK117141002 Minor Service Kit SC 7 15 C EK117141003 Mi...

Страница 2: ...operating instructions 0 Important safety information 4 0 1 Mechanical hazards 4 0 2 Electrical hazards 4 0 3 Thermal hazards 4 0 4 Hazards caused by materials and substances 4 1 Replace the tip seal...

Страница 3: ...itions described in the Operating Instructions It must be operated and maintained by trained personnel only Consult local state and national agencies regard ing specific requirements and regulations A...

Страница 4: ...azards caused by materials and substances 1 If within the system toxic substances or gases are being used then the operator will be responsible for ensuring that the corresponding safety precautions a...

Страница 5: ...t control for one hour to remove any process gases 1 Switch off the pump and isolate from the electrical supply 2 Using a 4 mm Allen key undo the two screws Figure 1 item 1 which secure the fan cowl a...

Страница 6: ...ure 3 item 1 which secure the fixed scroll assembly to the housing assembly 5 Carefully separate the fixed scroll assembly from the housing assembly using a suitable lever in the slots provided Figure...

Страница 7: ...ring groove when removing the O ring 7 Using a clean dry lint free cloth and IPA remove all dust and process debris from the scroll forms and grooves Heavier process debris can be removed with Green...

Страница 8: ...annel while working your way around the channel profile until you have reached the end Ensure the tip seal is pressed squarely and fully home at each pinch point these are located closer to the centre...

Страница 9: ...t the fixed scroll is fitted squarely onto the housing assembly 11 Tighten the fastening screws Figure 5 item 6 in small increments using a 4 mm Allen key and pull up evenly the fixed scroll assembly...

Страница 10: ...figure 9 item 3 Do not use any oil or lubricant during the assembly 4 Assemble to the top of the fixed scroll using an adjustable pin spanner Torque each screw to 6 Nm If no torque tool is available c...

Страница 11: ...nents back Note Do not to damage or trap the O ring figure 10 item 2 and 3 Do not use any oil or lubricant during the assembly 10 Assemble knob and exhaust valve assembly to the side of the fixed scro...

Страница 12: ...7 1250 info leybold com www leybold com Leybold Services Worldwide available We are continuously expanding our service network The current contact details can be obtained on our website Your contact w...

Отзывы: