Power On
Before turning on the power supply:
■
Make sure all wires are connected properly.
■
Make sure no screws, loose wire ends or tools are left in the frequency
converter.
After turning the power on, the frequency converter mode display should
appear and no fault or alarm should be displayed.
■
Connect X103-1 with X103-2 to activate, see Section 3.6.
■
Connect X103-3 with X103-5 to start.
The frequency converter is programmed specifically for this pump. The
parameter access is therefore limited. The default output frequency can be
changed in the programming mode between 0 Hz and 110 Hz (DV 200), or
125 Hz (DV 300), or 250 Hz (DV 500).
Description
Parameter
in Programming mode
Leybold setting
Standard output
frequency reference
d1-01
110 Hz for DV 200
125 Hz for DV 300
250 Hz for DV 500
The pre-set limiting parameters, in particular the maximum speed, must
not be changed. Note Safety Information in Section 0.2.
Do
not
run any auto-tuning on the frequency converter, since the pre-set
motor parameters are then lost.