121 errors
121 error messages
Error code
Description
Action
121.07
Fuser has been on for more than allowed after a gap
blowout, and the temperature is still too cold.
Go to
“Fuser service check” on page 87
.
121.08
Fuser was under temp when page was in fuser.
121.20
Fuser undertemp during steady state control. Can
occur in printing or standby modes.
121.22
Fuser did not warm enough to start line voltage
detection.
121.23
Fuser took too long to heat to line detection temp.
121.24
Fuser never reached detection temperature.
121.25
After line voltage detection, control did not roll over
to steady state control in time.
121.26
Failed to reach temperature during warm up.
121.28
Failed to reach EP warm up temperature in time.
121.29
Fuser failed to reach pre
‑
heat temperature for motor
start during warm up.
121.30
Fuser failed to reach printing temperature by the time
a page reached the fuser.
Go to
“Fuser service check” on page 87
.
121.31
Fuser is too hot. Global temperature check.
121.32
Open fuser main thermistor.
121.33
Open fuser edge thermistor.
121.34
Open fuser backup roll thermistor.
121.35
Attempting to POR after receiving a 121.34.
121.36
Fuser did not heat to allow compression jog.
121.37
Fuser heated faster than allowed during line voltage
detection.
Fuser service check
Action
Yes
No
Step 1
a
Restore the engine settings to their defaults:
Diagnostics Menu
>
Printer Setup
>
Defaults
b
Restore the EP setup settings to their defaults:
Diagnostics Menu
>
EP Setup
>
Defaults
Does the problem remain?
Go to step 2.
The problem is solved.
4514
Diagnostic information
87
Содержание M1140
Страница 18: ...4514 18 ...
Страница 20: ...4514 20 ...
Страница 30: ... Spring hook Feeler gauges Analog or digital multimeter Flashlight optional 4514 General information 30 ...
Страница 142: ...4514 142 ...
Страница 175: ...5 Remove the three screws B and then remove the left front mount B 4514 Repair information 175 ...
Страница 193: ...5 Remove the four screws B and then remove the right front mount B 4514 Repair information 193 ...
Страница 197: ...b Set the spring over the plunger 4514 Repair information 197 ...
Страница 204: ...3 Squeeze the latches B to release the left and right links B 4514 Repair information 204 ...
Страница 224: ...c Bring the cable in front of the two cable holders near the ACM shaft 4514 Repair information 224 ...
Страница 228: ...10 Remove the screw C and then detach the trailing edge sensor A 4514 Repair information 228 ...
Страница 229: ...11 Disconnect the two springs D 4514 Repair information 229 ...
Страница 231: ...15 Rotate and then remove the 2nd pickup bushing 16 Pull out the shaft and remove the ACM 4514 Repair information 231 ...
Страница 246: ...3 Swing the right cover backward to remove 4 Remove the screw D 4514 Repair information 246 ...
Страница 248: ...4514 248 ...
Страница 253: ...4514 253 ...
Страница 255: ...Assembly 1 Covers 4514 Parts catalog 255 ...
Страница 257: ...Assembly 2 Electronics 1 4514 Parts catalog 257 ...
Страница 259: ...Assembly 3 Electronics 2 4 3 2 1 6 5 4514 Parts catalog 259 ...
Страница 261: ...4514 Parts catalog 261 ...
Страница 262: ...Assembly 4 Frame 4514 Parts catalog 262 ...
Страница 264: ...4514 Parts catalog 264 ...
Страница 265: ...Assembly 5 Option trays 3 4 5 6 1 2 4514 Parts catalog 265 ...
Страница 268: ...4514 Parts catalog 268 ...
Страница 270: ...4514 270 ...
Страница 274: ...4514 274 ...
Страница 276: ...4514 276 ...
Страница 298: ...4514 Part number index 298 ...
Страница 302: ...4514 Part name index 302 ...
Страница 303: ......