Action
Yes
No
Step 9
Does the error remain?
Contact the next level
of support.
The problem is solved.
Sensor (input) image jam service check
Action
Yes
No
Step 1
Check the LSU cables for proper connection.
Are they properly connected?
Go to step 2.
Reseat the cables.
Step 2
Inspect the LSU cables and connectors.
Are they free of damage?
Go to step 3.
Replace the LSU. See
“Laser scanning unit
(LSU) removal” on
page 240
.
Step 3
Check the input sensor cable for proper connection.
Is it properly connected?
Go to step 4.
Reseat the cable.
Step 4
POR into the Diagnostics menu and perform a feed test:
Diagnostics Menu
>
Input Tray Tests
>
Feed Tests
>
Tray 1
Does it pass the test?
Go to step 5.
Replace the LSU. See
“Laser scanning unit
(LSU) removal” on
page 240
.
Step 5
POR into the Diagnostics menu and perform a sensor test:
Diagnostics Menu
>
Base Sensor Test
>
Input
Does the sensor state on the control panel display change when it is
toggled?
Go to step 6.
Replace the input
sensor. See
“Duplex
sensor and input
sensor removal” on
page 219
.
Step 6
Check the controller board for any damage.
Is it free of damage?
Go to step 7.
Replace the controller
board. See
“Controller
board removal” on
page 187
.
Step 7
Does the error remain?
Contact the next level
of support.
The problem is solved.
4514
Diagnostic information
49
Содержание M1140
Страница 18: ...4514 18 ...
Страница 20: ...4514 20 ...
Страница 30: ... Spring hook Feeler gauges Analog or digital multimeter Flashlight optional 4514 General information 30 ...
Страница 142: ...4514 142 ...
Страница 175: ...5 Remove the three screws B and then remove the left front mount B 4514 Repair information 175 ...
Страница 193: ...5 Remove the four screws B and then remove the right front mount B 4514 Repair information 193 ...
Страница 197: ...b Set the spring over the plunger 4514 Repair information 197 ...
Страница 204: ...3 Squeeze the latches B to release the left and right links B 4514 Repair information 204 ...
Страница 224: ...c Bring the cable in front of the two cable holders near the ACM shaft 4514 Repair information 224 ...
Страница 228: ...10 Remove the screw C and then detach the trailing edge sensor A 4514 Repair information 228 ...
Страница 229: ...11 Disconnect the two springs D 4514 Repair information 229 ...
Страница 231: ...15 Rotate and then remove the 2nd pickup bushing 16 Pull out the shaft and remove the ACM 4514 Repair information 231 ...
Страница 246: ...3 Swing the right cover backward to remove 4 Remove the screw D 4514 Repair information 246 ...
Страница 248: ...4514 248 ...
Страница 253: ...4514 253 ...
Страница 255: ...Assembly 1 Covers 4514 Parts catalog 255 ...
Страница 257: ...Assembly 2 Electronics 1 4514 Parts catalog 257 ...
Страница 259: ...Assembly 3 Electronics 2 4 3 2 1 6 5 4514 Parts catalog 259 ...
Страница 261: ...4514 Parts catalog 261 ...
Страница 262: ...Assembly 4 Frame 4514 Parts catalog 262 ...
Страница 264: ...4514 Parts catalog 264 ...
Страница 265: ...Assembly 5 Option trays 3 4 5 6 1 2 4514 Parts catalog 265 ...
Страница 268: ...4514 Parts catalog 268 ...
Страница 270: ...4514 270 ...
Страница 274: ...4514 274 ...
Страница 276: ...4514 276 ...
Страница 298: ...4514 Part number index 298 ...
Страница 302: ...4514 Part name index 302 ...
Страница 303: ......