18
46D0232
46D0232
19
�
�
�
�
�
�
VENT INSTALLATION
VERTICAL TERMINATION CONFIGURATIONS
Figures 23 through 26
on pages 19 and 20 show four different configurations for vertical termination.
IMPORTANT: You must install a restrictor on all vertical installations.
Figure 23 - Vertical Rigid Venting
Configuration Using Two 90° Elbows
Horizontal (H)
Vertical (V)
+ Horizontal (H
1
)
8' minimum
2' maximum
9' minimum
4' maximum
10' minimum
6' maximum
11' minimum
8' maximum
23' maximum
8' maximum
Figure 24 - Vertical Rigid Venting Configuration Using Three
90° Elbows with Two Horizontal Runs
Vertical (V)
Horizontal (H)
8' minimum
2' maximum
9' minimum
4' maximum
10' minimum
6' maximum
11' minimum
8' maximum
23' maximum
8' maximum
NOTE: Install restrictor into 4" collar of
stove or first vent section as shown.
NOTE: Install restrictor into 4"
collar of stove or first vent secton
as shown.
Table 5 - Venting with Two 90° Elbows
Table 6 - Venting with Three 90° Elbows