background image

36                                                                                                                                                                                 

46D0232

46D0232                                                                                                                                                                                                    

37

Failure to position the parts in accordance with these diagrams or failure to 
use only parts specifically approved with this appliance may result in property 
damage or personal injury.

W

ARNING

   

 

SS38DV[B,G]F(N,P) 

SS38DV[B,G](N,P)

REPLACEMENT PARTS ARE AVAILABLE THROUGH YOUR RETAILER

REPLACEMENT PARTS

 Item  Description 

QTY 

Natural 

Propane 

Natural  

Propane

  1

 

Burner Assembly 

46D0177 

46D0177 

46D0177 

46D0177

  2 

Left Log Support Bracket 

46D0251K 

46D0251K 

46D0251K 

46D0251K

  3 

Right Log Support Bracket 

46D0252K 

46D0252K 

46D0252K 

46D0252K

  4 

SIT 820 Nova Valve 

37D0117 

37D0118 

37D0117 

37D0118

  5 

Injector 

          57D0209

 

          57D0680

 

          57D0209

 

           57D0680

  6 

Venturi 

45D0

600

 

45D0

600

 

45D0

600

45D0

600

  7 

Tube Valve/Burner 

45D0085K 

45D0085K 

45D0085K 

45D0085K

  8 

Pilot Assembly 

37D0018 

37D0019 

37D0018 

37D0019

  9 

Rocker Switch 

41D0048 

41D0048 

41D0048 

41D0048

  10 

Formed Glass 

46D0159 

46D0159 

46D0159 

46D0159s

  11 

Air Shutter Rod 

46D0211 

46D0211 

46D0211 

46D0211

  12 

Air Shutter Knob 

45D0237 

45D0237 

45D0237 

45D0237

  13 

Knob Extension HI/LO 

43D0095 

43D0095 

43D0095 

43D0095

  14 

Knob Extension ON/OFF 

43D0094 

43D0094 

43D0094 

43D0094

  15 

Ignitor Battery Module 

45D0077 

45D0077 

45D0077 

45D0077

  16 

Ignitor Wire Harness 

44D0500 

44D0500 

44D0500 

44D0500

  17 

ON/OFF Wire Harness  

45D0565 

45D0565 

45D0565 

45D0565

  18 

Louver

s

 

                                        1

 

46D0

704

 

46D0

704

 

46D0

704            

46D0

704

  19 

Burner Gasket Set 

45D0027 

45D0027 

45D0027 

45D0027

  Logs

  20 

Center Log 

46D0222 

46D0222 

46D0222 

46D0222

 

21 

Rear Log 

46D0217 

46D0217 

46D0217 

46D0217

  22 

Right Bottom Log 

46D0219 

46D0219 

46D0219 

46D0219

  23 

Right Top Log 

46D0221 

46D0221 

46D0221 

46D0221

  24 

Left Top Log 

46D0220 

46D0220 

46D0220 

46D0220

  25 

Left Bottom Log 

46D0218 

46D0218 

46D0218 

46D0218

  Available Not Shown 

 

 

Vertical Restrictor 

45D0551 

45D0551 

45D0551 

45D0551

 

 

Ceramic Glass Center  

 

 

46D0160 

46D0160

 

 

Ceramic Glass Side 

 

 

46D0158 

46D0158

 

 

Engine Gasket Set 

45D0033 

45D0033 

45D0033 

45D0033

  Accessories 

 

 

Propane Gas Conversion Kit 

SS38CKP 

 

SS38CKP

 

 

Natural Gas Conversion Kit 

 

SS38CKN 

 

SS38CKN

Содержание STRATFORD SS38DV

Страница 1: ...age Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier This appliance is only for use with the type of gas indicated on the...

Страница 2: ...25 Operating Instructions 29 What To Do If You Smell Gas 29 Lighting Pilot for the First Time 29 Lighting Pilot 30 Lighting Burner 30 To Turn Off Gas 31 Maintenance 32 Venting System 32 Cleaning Glass...

Страница 3: ...d If this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakage can occur CARBON MONOXIDE POISONING Early signs of carbon monoxide...

Страница 4: ...nings into the combustion chamber along with adequate accessibility clearance for servicing and proper operation 17 When the appliance is installed directly on carpeting tile or other combustible mate...

Страница 5: ...onnected to a venting system The appliance is not approved for closet or recessed installations For alcove installation see Clearances page 8 Hi Lo Knob PRODUCT SPECIFICATIONS The efficiency rating of...

Страница 6: ...Supply Pressure 11 SS38 A 261 2 B 17 C 311 2 D 331 2 Figure 2 External Stove Dimensions STOVE DIMENSIONS NOTE If this unit is installed in a mobile home it must be bolted securely to the floor with le...

Страница 7: ...fort centrally locate the stove in a large and open room The flow of combustion and ventilation air must not be obstructed Minimum clearances to combustibles side wall ceiling woodwork and windows mus...

Страница 8: ...r vinyl flooring the appliance shall be installed on a metal wood or noncombustible material panel extending full width and depth of the appliance WARNING CLEARANCES Figure 4 Clearances to Side Back a...

Страница 9: ...ction Use extreme caution when using ladders or when on rooftops Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system Insta...

Страница 10: ...5 elbows up to a maximum of 270 For two story applications firestops are required at each floor level If an offset is needed in the attic additional pipe and elbows will be required You may use a chas...

Страница 11: ...e to unventilated soffits 12 305mm minimum Clearance to vinyl soffit 30 762mm F Clearance to an outside corner See page 12 G Clearance to an inside corner See page 12 H Not to be installed above a gas...

Страница 12: ...D0232 VENT INSTALLATION TERMINATION CLEARANCES FOR BUILDINGS WITH COMBUSTIBLE AND NONCOMBUSTIBLE EXTERIORS Figure 7 Allowable Venting Chart NOTE Any vent configurations with the shaded areas are accep...

Страница 13: ...ure 9 Do not back fill around the snorkel termination 2 Rigid vent pipes and fittings have special twist lock con nections Assemble the desired combination of pipe and elbows to the appliance adaptor...

Страница 14: ...bles is maintained Attach the vent cap with four wood screws supplied See Figure 12 Do not recess vent termination into any wall This will cause a fire hazard WARNING For vinyl siding stucco or wood e...

Страница 15: ...ONTAL VENT INSTALLATION CONTINUED Interior Wall Surface Decorative Wall Thimble Horizontal Vent Pipe Screw Vent Cap Horizontal Termination HORIZONTAL TERMINATION CONFIGURATIONS Figures 15 through 17 s...

Страница 16: ...r Rigid Venting Using Two 90 Elbows Horizontal H Vertical V V1 Horizontal H1 5 minimum 4 maximum 6 minimum 6 maximum 8 minimum 10 maximum 20 maximum 12 maximum VENTING WITH THREE 90 ELBOWS Figure 17 H...

Страница 17: ...d to 91 2 x91 2 241mm x 241mm inside dimensions as shown in Figure 20 using framing lumber the same size as the ceiling joist If the area above the ceiling is an insulated ceiling or a room nail fires...

Страница 18: ...ure 21 Cathedral Ceiling Support Box Installation Figure 22 Installed Cathedral Ceiling Support Box CATHEDRAL CEILING INSTALLATION IMPORTANT Review all information on previous page before planning thi...

Страница 19: ...imum 2 maximum 9 minimum 4 maximum 10 minimum 6 maximum 11 minimum 8 maximum 23 maximum 8 maximum Figure 24 Vertical Rigid Venting Configuration Using Three 90 Elbows with Two Horizontal Runs Vertical...

Страница 20: ...nt vent section as shown NUMBER DESCRIPTION NUMBER DESCRIPTION 902B 7 x 48 Pipe 943S Roof Flashing 7 12 12 12 903B 7 x 36 Pipe 945B 7 x 45 Elbow 904B 7 x 24 Pipe 950 Vinyl siding Standoff 906B 7 x 12...

Страница 21: ...e to gas supply Follow all local codes WARNING INSTALLATION ITEMS NEEDED Before installing stove and burner system make sure you have the items listed below External regulator supplied by installer Pi...

Страница 22: ...in supply line as shown in Figure 28 Locate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and burner system Locate sediment trap drip leg w...

Страница 23: ...HI to get maximum pressure to burner Turn HI LO knob to LO to get minimum pressure 5 To check gas pressures at valve turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressu...

Страница 24: ...NSTALLATION ELECTRICAL WIRING Electrical connections should only be performed by a qualified licensed electrician Main power must be off when connecting to main electrical power supply or performing s...

Страница 25: ...After handling the logs wash your hands gently with soap and water to remove any traces of fibers The positioning of the logs is critical to the safe and clean operation of this heater Sooting and oth...

Страница 26: ...See Figure 34 6 Place top left log on left base log Line up the hole in the bottom of the top log with the locating pins on the bottom log See Figure 35 LOG PLACEMENT Figure 34 Installing Right Base...

Страница 27: ...Right Log Top Center Log LOG PLACEMENT 7 Place top right log on right base log Line up the holes in the bottom of the top log with the locating pins on the bottom log See Figure 36 8 Place top center...

Страница 28: ...d Rock Wool Rock Wool Figure 38 Installing Rock Wool Embers 9 Break up rock wool ember material into dime sized pieces Place evenly across burner surface and mesh of grate See Figures 38 and 39 Do not...

Страница 29: ...lt in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service tech nician to inspect the appliance and to replace any part of the co...

Страница 30: ...he magnet is closed it is possible to start the lighting operation The gas control knob is designed to be operated by hand DO NOT use any tools during this operation Damaged knobs may result in seriou...

Страница 31: ...rn off the main burner without using the gas valve knob Make sure the button is in the ON position to light the main burner See Figure 41 LIGHTING THE BURNER Depress and turn the knob counterclockwise...

Страница 32: ...re 46 for typi cal pilot flame Let glass cool before cleaning Do not clean glass when it is hot Damage could occur CAUTION Make sure the gas valve knob is in the OFF position Wait at least five 5 minu...

Страница 33: ...or high altitude as follows To increase air mixture push up the adjustment rod located beneath the stove This opens the shutter more and will stop or minimize sooting See Figure 47 To decrease air mix...

Страница 34: ...ece glass style frame slide new glass into the 45 aluminum post not shown 7 Fasten retaining brackets back into place with 5 16 nuts 8 Replace 7 8 rope Make sure the joint is at the bottom and there i...

Страница 35: ...46D0232 35 BLOWER BLOWER WIRING DIAGRAM FOR BLOWER...

Страница 36: ...36 46D0232 REPLACEMENT PARTS...

Страница 37: ...Shutter Rod 1 46D0211 46D0211 46D0211 46D0211 12 Air Shutter Knob 1 45D0237 45D0237 45D0237 45D0237 13 Knob Extension HI LO 1 43D0095 43D0095 43D0095 43D0095 14 Knob Extension ON OFF 1 43D0094 43D009...

Страница 38: ...fromtheelectrode to pilot Adjust by loosening screws on pilot base Adjust and retighten 4 Replace with new wire 1 A Check for proper connection of ther mocouple to rear of valve B Check thermocouple o...

Страница 39: ...THE INSTALLER FOR WARRANTY PURPOSES AND FUTURE REFERENCE LEXINGTON FORGE Model _____________________________ Name of Owner Name of Installer Address Address Phone Phone Name of Dealer Address Phone M...

Страница 40: ...ve finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of ins...

Страница 41: ...d in whole or in part for residential purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manu facturer of Product Approved side wall horizontally vented gas equipment...

Страница 42: ...or authorized service center shipping damage damage from improper use or neglect installation damage damage from unauthorized service incidental or consequential damage or negative pressure caused by...

Отзывы: