Setting manner two:Remote control
①
SENS
ON: press ON, the load connected will keep working for 6 hours
and then automatically turn to AUTO mode.
OFF: press OFF, the load connected will be off for 6 hours and
then automatically turn to AUTO mode.
AUTO: press AUTO, sensor enters the auto-detecting mode,
that is, when signal detected and the ambient light intensity is
lower than the preset value, the load works.
Friendly reminder: there are two manners to define its function and the last definition will be
effective and still be valid even if the sensor restarts.
Warning!
1
、
Being installed on the rocking object will lead to error reaction.
2
、
The shaking curtain blown by wind will lead to error reaction. Please select the suitable place to install.
3
、
Being installed where the traffic is busy will lead to error reaction.
4
、
The sparks produced by some equipment nearby will lead to error reaction.
The following situations will lead to error reaction
.
Fault and the solution
The load fails to work.
Light-illumination is set incorrectly
.
Adjust the setting of the load.
Change the load.
Turn the power on.
Check the settings of the
detection area.
Re-adjust the installation place.
Check the settings of the
detection area.
Check the settings of the
detection area.
The load is broken.
The power is off.
There is a continuous signal in the region of the detection.
Moving signal is detected by the sensor (movement
behind the wall, the movement of small objects, etc.)
The lamp isn't installed well so that sensor fails to
detect reliable signals.
The motion speed is too fast or the defined detection
area is too small.
Fault
Failure cause
Solution
The load works all the time.
The load works when there is
no motion signal detected.
The load fails to work when
there is motion signal detected.
Note:
please don’t adjust the three functional knobs to excess. That is because the three
functional knobs were connected to the components directly, there is a small stopper in each
of the three components, when you adjust the knobs from start to end, the excessive turn
will damage the stopper
,
and lead to the 360°non-stop turn around. The adjust range limit is
270°, please do pay attention to this.
(3)Light-control setting
It can be defined in the range of 10~1000 LUX. To turn the knob fully anti-clockwise is
about 10 lux,fully clockwise is about 1000 lux.When adjusting the detection zone and
performing the walk test in daylight,you should turn the knob fully clockwise.
10-1000LUX