Automatic Learning Function

1. Learn function executes automatically and 

    runs for approximately 3 minutes when the 

    batteries are first installed in the receiver.

2. Within these 3 minutes, the receiver picks up 

    the temperature & humidity signals from the 

    remote sensor and displays the readings.

Manual-Learning (Searching for Remote Signals)

If a new remote sensor is added or if the signal is 

lost (outdoor display blinking), the learning function must be executed again.

1. Press and hold 

CHN [4]

 for 3 seconds to start.

2. A beep sound indicates that the learning function has started.

3. The 'Channel' symbol will flash and unit will beep as each remote sensor 

    is detected.

4. Temperature & humidity readings of remote sensor are displayed on the receiver.

Note: Auto/Manual Learn will not operate while the radio controlled clock is receiving DCF77 or MSF 

signals.

Copyright © Lexibook 2006 

SM1760IM0036 GB5

English

English

5

1

2

3

4

5

6

7

8

GETTING STARTED

SETUP

Copyright © Lexibook 2006 

SM1760IM0036 GB6

6

LOW BATTERY INDICATION:  

If the batteries of the remote sensor are low, the following indicator   

will be displayed on the main unit. The indicator will also be displayed on the bottom left corner of the 

remote sensorʼs screen. When the main unitʼs LCD display becomes dim, it indicates that the batteries 

are low and need to be changed. 

Note: if the sensor is exposed to very low temperatures for an extended period of time, the batteries 

may lose power which may cause the transmission range to be limited. High temperatures also reduce 

the battery performance. 

Setting the remote sensor

Unscrew the battery cover and insert batteries to begin the settings. 

The house code

 will flash for 8 seconds. 

Select 

a house code

 (1-15) by pressing 

°C/°F

 [8] and then press 

SET [7]

. The house code is the frequency signal sent by the 

remote sensor to the receiver. The remote sensors for each 

receiver must be set to the same house code, and remember to 

press 

SET

The channel

 will flash for 8 seconds. 

Select a 

channel

 (1-3) by pressing 

°C/°F

 [8] and then press 

SET

 [7].  The channel 

function allows the receiver to identify each remote sensor. Each receiver can receive 

up to 3 different remote channels. The preferred channel number (1, 2 or 3) for each individual 

remote sensor can be assigned. However, channel 1 is used for collecting data from outdoor and 

activating the weather forecast symbols. If you only have one remote sensor, please set it at 

channel 1 and place it outdoors.  
Humidity and temperature will be displayed.
Toggle between °C or °F temperature display by pressing 

°C/°F 

key [8].

Insert 3 x AA batteries at the back of the main unit. 

Notes: 

• The SM1760 comes with one receiver and one remote sensor. If you wish to buy additional sensors 

   please refer to the section ACCESSORIES at the end of this manual.

• Use a different house code if your weather station detects other signals from neighbouring sources. 

   Else, use default settings: house code = 01  and channel = 01

Содержание MeteoClock Wall Deco SM1760

Страница 1: ...try for a given temperature between 18 and 24oC Barometer The station also monitors the atmospheric pressure in real time It displays the weather forecast by means of animated icons sun clouds rain and for the next 8 to 12 hours And many extra features Main Display Unit SM1760 n Auto synchronizing radio controlled clock DCF 77 and MSF n Perpetual Calendar n Inside and outside temperature and humid...

Страница 2: ...ff disables resets high low temperature alarms Alarm snooze Main LCD display with backlight SET enter House code and Channel setting mode C F change between C or F change channel and house code Battery compartment DCF MSF RCC Switch Select MSF for use in the UK and Ireland LCD display Remote sensor Wall Mount Holder Tabl e Stand Display layout Main Unit Remote Sensor Your Meteoclock works with 3 A...

Страница 3: ...y low temperatures for an extended period of time the batteries may lose power which may cause the transmission range to be limited High temperatures also reduce the battery performance Setting the remote sensor Unscrew the battery cover and insert batteries to begin the settings The house code will flash for 8 seconds Select a house code 1 15 by pressing C F 8 and then press SET 7 The house code ...

Страница 4: ...al The DCF77 signal will be received if the main unit is within 1500 km of the Frankfurt atomic clock Your main unit will be automatically synchronised with the MSF signal if located within the UK radio signal range 1 The clock automatically starts scanning the RF 433MHz signal after new batteries are inserted in the main unit When receiving radio signal the Radio Tower symbol starts to blink A co...

Страница 5: ... the alarm for 5 minutes After that the alarm will sound again c Press ANY other key to turn the alarm sound off If not manually interrupted the alarm sound will automatically stop after one minute Copyright Lexibook 2006 SM1760IM0036 GB9 English English 9 1 2 1 2 1 2 3 3 4 ALARM SETTING MOON PHASES TEMPERATURE HUMIDITY DISPLAY Copyright Lexibook 2006 SM1760IM0036 GB10 10 Throughout the 28 days of...

Страница 6: ...D TEMPERATURE ALARM Copyright Lexibook 2006 SM1760IM0036 GB12 12 The trend indicator shows the trend of temperature humidity determined by the particular sensor in the past half hour interval Arrow Indicator Trend Rising Steady Falling You can set high temperature or low temperature alarms for one local channel and for one remote channel Local temperature alarm Scroll to temperature alarm mode by ...

Страница 7: ... latter are expressed in hPa at sea level i e zero altitude Ambient pressure varies according to altitude hence the altitude at which your home stands is important This is why it is possible and perfectly normal to notice a small difference between the pressure displayed by the MeteoClock SM1760 unit not corrected to the local altitude and the official values broadcasted by the national weather ag...

Страница 8: ...ature trend press Snooze 5 in Clock1 mode The sequence is Pressure Trend Inside Temperature Trend Outside Temperature Trend Note The weather forecast by the means of the animated icons depends on the evolution of the barometric pressure By consulting the barometric pressure historical graph you can evaluate the likeliness or the strength of the weather forecast currently displayed For example if t...

Страница 9: ...a beep is heard 3 Ensure the remote sensor is out of direct sunlight and away from sources of heat 4 Repeat the learning procedures Temperature may be below 30 C Batteries in remote sensor may need changing Move remote sensor closer to the receiver Make sure remote sensor is away from sources of electrical disturbance 5 Reset the unit by replacing the batteries in both the transmitters and receive...

Страница 10: ...sed work on the equipment such as dismantling exposure to heat or damp etc For technical assistance call 0808 100 3015 Web http www lexibook co uk Email infouk lexibook com Environmental Protection Unwanted electrical appliances can be recycled and should not be discarded along with regular household waste Please actively support the conservation of resources and help protect the environment by re...