10

3. Function introduction

Main Interface

Basic operation interface

1.

2.

After you connect to the computer, select "COM3"

(COM3 will appear when the connection is normal),

the baud rate is the default value, and then click

"Open Port", the left indicator light turns green,

indicating the connection is successful (The blue

light on the top of the bus servo will always light,

indicating everything is normal).

The right interface of

this window shows the

current

position

and

temperature of the servo

and the battery voltage.

Содержание LX-16A

Страница 1: ...1 LX 16A Bus Servo User Manual...

Страница 2: ...s Net weight 52 g 1 8oz Product size 1 78in 0 97in 1 38in Rotation speed 0 18sec 60degree 6v 0 16sec 60degree 7 4v Servo accuracy 0 24 Torque 15kg cm 208oz in 6V 17kg cm 236oz in 7 4 Servo ID 0 253 us...

Страница 3: ...d 6 1 Brief introduction 6 2 Install driver 6 3 The introduction of the debug board 7 4 Connection diagram 8 Bus Servo Debug System 9 1 Brief introduction 9 2 Installation 9 3 Function introduction 10...

Страница 4: ...d making the robot run more stable The life expectancy of the servo is also significantly increased 4 Read angle LX 16A servo has the function of angle feedback support angle read back you can quickly...

Страница 5: ...tion of the bracket so that the robot joint can move steadily 9 Metal gear The high speed output of the Internal DC motor obtain a greater torque through the 5 stage reduction ratio And high precision...

Страница 6: ...y bus servos you need to control all you need to use is a debug board The use of the debug board requires the debug software please refer to the Debugging Software section 2 Install driver You need to...

Страница 7: ...e servo with the debug board by connecting to the TXD and RXD of the single chip LX 16A servo has three wires positive negative and signal wire respectively This signal wire can receive and send data...

Страница 8: ...8 4 Connection diagram...

Страница 9: ...ervo In other words we can use bus servo normally only after setting up ID number for bus servo 2 Installation Double click the icon the interface is shown below 1 You need to install dotNetFx40_Clien...

Страница 10: ...is normal the baud rate is the default value and then click Open Port the left indicator light turns green indicating the connection is successful The blue light on the top of the bus servo will alway...

Страница 11: ...tates the faster you drag the faster the servo rotates Time set the rotation time of the servo the greater the time value the slower the rotation of the servo Drag the slider to chance the speed value...

Страница 12: ...n range is 0 to 240 degrees Changing this value allows you to adjust the rotation range of the servo For example if you drag the slider to 500 value and don t change the drag the slider located below...

Страница 13: ...s running normally the blue light is on and the blue light flashes when over heat over voltage or locked rotor occurs Tick to determine whether the light will alarm the selected status Set the voltage...

Страница 14: ...us serial interface realizes the half work asynchronous serial bus communication the communication baud rate is 115200bps and the interface is simple the protocol is simplified In your own designed co...

Страница 15: ...deo tutorial if the problem still can not be solved please feel free to contact us by email at support lewansoul com Please visit the following link or scan the QR codes to get related instructions an...

Отзывы: