 CONTROL

INSTALLATION GUIDE

Remove the back of the device 
by removing the 4 screws on it.

Insert  the  pre-wired  temperature 
s e n s o r   i n t o   t h e   m e a s u r i n g 
opening  of  the  water  tank. 
(Internal Sensor)

Insert the connected sensor into 
the measuring hole of the solar 
collector. (External Sensor) If it is 
short,  extend  the  sensor  cable 
up to 300m long.

Connect the pump to the 
controller. Attention, the input 
voltage is displayed on it! The 
device must not be connected 
to the mains voltage during 
installation.

Connect the device's power 
cable to a power outlet. Check 
that the device is working, the 
Power ON led should light up.

Once you have assembled the 
configuration shown in the image, 
follow the configuration instructions 
on the next page.

T2

T

1

Power ON

P

ump ON

Error

WATER TANK

 TEMP

COLLECTOR

 TEMP

SOLAR

 

CONTROL

Содержание LSP-SC2-WIFI

Страница 1: ...SOLAR CONTROL WiFi VERSION LSP SC2 WIFI User Manual...

Страница 2: ...aying of measured temperatures The purpose of the LSP SC2 WIFI controller is to control a solar collector system consisting of a solar collector and a hot water storage tank By comparing the collector...

Страница 3: ...for testing the pump 5A fuse for the pump 500mA fuse for the power supply Display LED indications Pt1000 sensor from the collector Pt1000 sensor from the water tank Pump connection Max 4A 220V Power...

Страница 4: ...at intervals set in the parameter settings which can be distinguished by the appearance of the dot In the case of an error the display shows the code of the active error which is detailed in the error...

Страница 5: ...address bar of the browser e g Chrome Google Safari 192 168 4 1 If the browser has successfully opened the main page here we can see the main data about the system such as the current temperatures the...

Страница 6: ...Setup Here we can change or set the parameters of the controller to the default position You must enter a password to enter Username admin Password password Levtech Service Prodtuction SRL Settings...

Страница 7: ...parameters Low Temperature Hysteresis Filled with antifreeze this value determines by how many degrees the system must warm back up from the value speci ed in the Low temperature parameter in order fo...

Страница 8: ...s Celsius mostly during the night the controller starts the pump and it works until the temperature of the tank drops below 50 degrees Celsius Default button by clicking on this we can restore the con...

Страница 9: ...able window We can search for our network with the Scan button and then enter the password of our network in the Wi password eld By checking DHCP we can access the controller automatically without ent...

Страница 10: ...the list of Wi Fi devices when searching AP SSID here we can change the name of the device so that it appears in the list of available devices when searching AP Password we can change the connection p...

Страница 11: ...s enable Finally save your changes with the Save button at the bottom of the page Other changes to this menu item are only necessary in special cases E mail noti cations only work if the device is con...

Страница 12: ...e controller Solar_control The password is password Step 2 Scan the QR code at the bottom of the product or type the IP address 192 168 4 1 into your browser Chrome Google Safari Step 3 Enter the LAN...

Страница 13: ...has been properly switched o Step 2 Press and hold the AP button Button 2 While the button is pressed reconnect the device s plug to the mains socket Step 3 After connecting keep the button pressed fo...

Страница 14: ...of the collector is not connected open loop E S the sensor of the collector is shorted Sensor failure alarm Overheat alarm by default Once the solar collector temperature exceeds the Over Temperature...

Страница 15: ...perature Without Antifreeze of 4 C thus preventing freezing If the temperature in the solar collector exceeds 5 C the controller will return to normal mode Antifreeze mode is enabled by default so if...

Страница 16: ...Dimensions Levtech Service Prodtuction SRL 67 57 mm 129 92 mm 92 84 mm 141 64 mm 36 79 mm...

Страница 17: ...ed it is justi ed to dismantle splice and reassemble them The sensors can be extended to a length of up to 300 m without a ecting the accuracy of the measurement The polarity of the Pt1000 sensors doe...

Страница 18: ...0 C Dimensions H x L x W 147 x 96 x 38 mm Weight 185g 515g with accessories Display 3 character 7 segment display The pump max current consumption 4A Type of sensors Pt1000 Pt1000 Sensor wire length 3...

Страница 19: ...llector Antifreeze operating mode Pump starts at 20 C and stops at 15 C Fagy sg tl n lk li m d Pump starts at 4 C and stops at 5 C Pump shutdown delay 0 sec Temperature di erence 2 C Starting temperat...

Страница 20: ...htning strike the device may be destroyed Make sure that the device is not connected to the network during a storm We are committed to protecting the environment The production of electronic devices r...

Страница 21: ...If it is short extend the sensor cable up to 300m long Connect the pump to the controller Attention the input voltage is displayed on it The device must not be connected to the mains voltage during i...

Страница 22: ...ing the page you can see the current state of the system and from here you can open the parameter settings by clicking on the Setup button Username admin Password password After logging in there are t...

Отзывы: