User Manual for LEVIFLOW
®
LFS Flowmeters
www.levitronix.com
PL-4502-00, Rev11, DCO# 18-107
5
Pos.
Part Name
Part #
Shape
Flow
Fitting
(Tube)
Max. Liquid
Temperat.
Cable
Connector
Note
1a
LFS-008-Z / LFS-008-U
100-30323 / 100-30324
Z / U
0
– 0.8 lpm
1/4”
90 °C
FEP
0.5 m
PVDF male
connector
cover
Sensor specific
parameter for
converter calibration
are delivered on a tag
attached to the
flowsensor.
1b
LFS-04-Z-T025 / LFS-04-U-T025
100-30321 / 100-30322
Z / U
0
– 4 lpm
1/4”
90 °C
1c
1d
LFS-04-Z / LFS-04-U
LFS-04H-Z / LFS-04H-U
100-30304 / 100-30305
100-30330 / 100-30331
Z / U
0
– 4 lpm
3/8”
90 °C
180 °C
1e
1f
LFS-08-Z / LFS-08-U
LFS-08H-Z / LFS-08H-U
100-30306 / 100-30307
100-30332 / 100-30333
Z / U
0
– 8 lpm
3/8”
90 °C
180 °C
1g
1h
LFS-20-Z / LFS-20-U
LFS-20H-Z / LFSH-20-U
100-30308 / 100-30309
100-30372 / 100-30373
Z / U
0
– 20 lpm
1/2”
90 °C
180 °C
1i
1j
LFS-50-Z / LFS-50-U
LFS-50H-Z / LFS-50H-U
100-30310 / 100-30311
100-30340 / 100-30341
Z / U
0
– 50 lpm
3/4”
90 °C
180 °C
1k
1l
LFS-80-Z / LFS-80-U
LFS-80H-Z / LFS-80H-U
100-30312 / 100-30313
100-30342 / 100-30343
Z / U
0
– 80 lpm
1”
90 °C
180 °C
Table 1: Standard flow sensor models
Pos.
Article Name
Part #
Description
Interfaces
2a
(with 2c)
LFC-1C
100-30314
Single Channel Converter
(Interface connector 2c included)
Analog Output (4
– 20 mA), 2x Digital Output, 1x Digital Input, RS485 (MODBUS)
Note: LFC-1C-F4 works with LFS-008 only.
2b
(with 2c)
LFC-1C-F4
100-30325
3
LFC-6C
100-30315
6-Channel Converter
- RS485 (MODBUS)
- Order Bus Conn. (7a) and Terminat. Box (7b) as separate article (see Table 3)
Note: Does not work with LFS-008 sensor.
4
(with 4a
and 4b)
LFC-6CIO
100-30337
6-Channel Converter
with I/O Interfaces
(Digital I/O connector 4a and analog output
connector 4b included)
- RS485 (MODBUS) protocol
- 6 analog outputs (4
– 20 mA), 6 digital inputs, 6 digital outputs
- Order Bus Conn. (7a) and Terminat. Box (7b) as separate article (see Table 3)
- EMI ferrite (8) to be ordered as separate article (see Table 3)
Table 2: Standard converters
Pos.
Article Name
Part #
Features
Special Feature
5a
LFE-A.1-10
LFE-A.1-30
LFE-A.1-60
190-10162
190-10163
190-10164
Cable length: 1 m, PVC
Cable length: 3 m, PVC
Cable length: 6 m, PVC
- PP female connector cover for IP-65 chemical protection
- Flame retardant PVC white (UL VW-1 corresponds to EN-60332-1-2)
5b
LFE-A.2-10
LFE-A.2-30
LFE-A.2-60
190-10165
190-10166
190-10167
Cable length 1 m, FEP
Cable length 3 m, FEP
Cable length 6 m, FEP
- PP female connector cover for IP-65 chemical protection
6a
LFE-D.1-10
LFE-D.1-30
LFE-D.1-60
190-10296
190-10297
190-10298
Y cable, 1 m, PVC, cover
Y cable, 3 m, PVC, cover
Y cable, 6 m, PVC, cover
For lFC-6CIO with protective SMB connector PP cover.
6b
LFA-A.1
190-10268
Y adaptor cable, PVC
For LFC-6CIO
7a
Connector Box for LFC-6C
100-30316
COMBICON connector
For wiring RS485 and supply of stacks of LFC-6C and LFC-6CIO converters.
7b
Termination Box for LFC-6C
100-30317
--
For termination of RS485 bus of LFC-6C and LFC-6CIO.
8
LeviFlow Splitting Ferrite
100-30353
EMI filtering of DC supply
For LFC-6CIO supply needed.
9
USB to RS485 Adaptor-TR
Isolated YN-485I-TR
100-30392
Structure/Design
USB connector (9a) with termination resistor and cable with connector pair (9b
and 9c) for external RS485 wire connection. Isolated. Cable length is 2m.
Purpose
Communication over fieldbus of driver with PC
Table 3: Accessories
Pos.
Part Name
Part #
Flow
Range
Fitting
(Tube)
Max. Liquid
Temperat.
Cable
Note
9a
LFS-008-Z + LFC-1C-F4
LFS-008-U + LFC-1C-F4
100-90625
100-90626
0
– 0.8 lpm
1/4"
90 °C
FEP
0.5m
Converter is delivered with sensor
specific parameters already stored.
Extension cables to be ordered as
separate article with specified length
(see Table 3).
9b
LFS-04-Z-T025+LFC-1C
LFS-04-U-T025+LFC-1C
100-90627
100-90628
0
– 4 lpm
1/4"
90 °C
9c
LFS-04-Z+LFC-1C
LFS-04-U+LFC-1C
LFS-04H-Z+LFC-1C
LFS-04H-U+LFC-1C
100-90604
100-90605
100-90630
100-90631
0
– 4 lpm
3/8”
90 °C
90 °C
180 °C
180 °C
9d
LFS-08-Z+LFC-1C
LFS-08-U+LFC-1C
LFS-08H-Z+LFC-1C
LFS-08H-U+LFC-1C
100-90606
100-90607
100-90812
100-90813
0
– 8 lpm
3/8”
90 °C
90 °C
180 °C
180 °C
9e
LFS-20-Z+LFC-1C
LFS-20-U+LFC-1C
LFS-20H-Z+LFC-1C
LFS-20H-U+LFC-1C
100-90608
100-90609
100-90835
100-90836
0
– 20 lpm
1/2”
90 °C
90 °C
180 °C
180 °C
9f
LFS-50-Z+LFC-1C
LFS-50-U+LFC-1C
LFS-50H-Z+LFC-1C
LFS-50H-U+LFC-1C
100-90621
100-90622
100-90802
100-90714
0
– 50 lpm
3/4”
90 °C
90 °C
180 °C
180 °C
9g
LFS-80-Z+LFC-1C
LFS-80-U+LFC-1C
LFS-80-Z+LFC-1C
LFS-80-U+LFC-1C
100-90623
100-90624
100-90715
100-90716
0
– 80 lpm
1”
90 °C
90 °C
180 °C
180 °C
Table 4: Flowmeter sets
– flowsensor with single channel converter LFC-1C/LFC-1C-F4