User Manual for BPS-i600
www.levitronix.com
PL-4089-00, Rev00, DCO# 21-271
8
2.4 Pressure-Flow Curves
Figure 5: Pressure/flow rate curves
(Measured with pump head LPP-600.29)
2.5 Maximum Static Pressure for Pump Heads
Figure 6: Specification for maximum static pressure of pump head LPP-600.29
(Pressure limits only valid for pump head mounted on motor)
0
10
20
30
40
50
0.0
5.0
10.0
15.0
20.0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
0
20
40
60
80
[psi]
[gallons / min]
[bar]
[liters / min]
8000 rpm
9000 rpm
6000 rpm
7000 rpm
Specific gravity = 1 g/cm
3
Viscosity = 0.7 cP
Liquid Temp.: 40
°C
DC-Voltage = 48 V
DC
Pump Head: LPP-600.29
5000 rpm
0
20
40
60
80
100
120
77
87
97
107
117
127
137
147
157
167
177
187
0
1
2
3
4
5
6
7
8
9
25
30
35
40
45
50
55
60
65
70
75
80
85
90
[psi]
[°F]
[bar]
Liquid Temperature in [°C]
Pump Head LPP-600.29
Testing according to EN12162 including safety factors.
Limitation: Given by deformation. Burst pressure is significantly higher
Ambient Temp = 25
°C
Note: Pressure limit only valid for pump head mounted on motor