4.1.6 Installation of RS485 Fieldbus Multi-Pump System Arrays
shows a multi-pump system arrangement with the
RS485
fieldbus and its basic specifications.
Figure 16: Multi-pump system arrangement with RS485 fieldbus
Following points and information shall be considered:
➔
Testing has been done with arrangements of 8 pump systems. Higher number is possible but it is
recommended to contact
Levitronix
®
Technical Service
department (see
Section 8
) for details and support.
➔
Address setting of the pump units can be done with the
Levitronix
®
Service Software
and a
PC. A USB/RS485
converter cable with integrated initialization network can be ordered according to
➔
The
RS485
protocol for master communication is available at
Levitronix
®
on request.
➔
Do not use multiple master systems at the same time.
➔
Do not use closed ring arrangements.
4.2 Mechanical Installation
4.2.1 Mechanical Installation of Driver and Pump Head
The driver can be fixed with four screws on the motor feet (see
). Mounting can be done in either in
horizontal or vertical position. When mounting the pump head fittings into a circuit, care shall be taken that no
mechanical stress is acting on the fittings, which can result in distorting creeping effects.
!
WARNING
BPS-i600 pump drivers are not rated to be placed next to flammable
gases. Do not use the driver next to flammable gases.
4.2.2 Mechanical Installation of Water Cooling Module
The water cooling module
WCM-600.1
can be mounted to the driver top as illustrated in
. The cooling
liquid (for example water) can be connected over the two NPT 1/8” fittings (see
). A minimum cooling
liquid flow of 0.5 l/min at @
≤ 20°C temperature is recommended.
120
W
120
W
510
W
510
W
Master
Integrated
System
#1
Integrated
System
#2
Integrated
System
#N
5V
Branch Bus Lines:
Length sum of all < 33m.
Main Bus Line: < 100m
Shielded cable with drilled wires recommended.
Termination:
Recommended for main bus line Length > 5m.
Initialization Network:
Always recommended.
To be implemented at the master.