1. Bootloader XX.YY
BOOTLOADERAPPLICATIONISRUNNING8899INDICATESTHEAPPLICATIONVERSION
2. Reading File
READINGTHEPROGRAMMINGlLEFROMTHE3$CARD
3. Checking File
- validating file against flash.
4. Interactive
WAITINGFORCOMMANDSFROMTHESERIALTERMINAL
5. Rebooting
REBOOTINGDEVICE
6. Launch App
- starting application.
7. Burn Internal
- reprogramming application.
8. Erase External
- reprogramming application.
9. Burn External
- reprogramming application.
10. Init Hardware
- initializing hardware.
11. Init File System
- initializing file system.
12. Init Ethernet
- initializing Ethernet.
13. Waiting for DHCP
WAITINGFOR$(#0TOGIVEANADDRESS
14. Configuring
CONlGURINGSUBSYSTEMS
15. Ready
- startup sequence complete.
16. Start Fail
THESTARTUPCONlGURATIONSCRIPTCOULDNOTBEREADFROMTHE3$CARD
17. LN:xxx CAN:yyy
- Luma-Net
®
(LN) and LumaCAN
TM
(CAN) address.
18. No Config
- no configuration stored.
19. WatchdogTimeout SSSS
SUBSYSTEM3333FAILEDWHERE3333ISANAME
20. Factory Defaults Total Clear
- a "Total Clear" press sequence was detected and executed.
21. Factory Defaults Configuration
- a "Configuration Clear" press sequence was detected and executed.
22. Rebooting…5
WILLREBOOTINSECONDS#ONTINUESTOCOUNTDOWNUNTILITREACHES3ECOND
23. Boot Failed…Retrying
THISISTHERESULTOFTHEDEVICENOTCOMPLETINGTHESTARTUPSEQUENCEAFTERTENMINUTES
Page 10
7.3 ADVANCED NETWORKING APPLICATION WITH BMS INTEGRATION
Sector Ballast
Line
Voltage
Power
Reset
Network Protocol Converter
NP00G
B
A
Ethernet Luma-Net®
MS/TP
LumaCAN®
Expansion
Error
Link/RX
TX
Luma-Net
Power Supply
Sector
Bus Controller
Power
SectorNet
Luma-Net
LumaCAN
GreenMax
Cabinet
+24vdc
+24vac
+24vdc
+Vac
+Vac
+Vac
LumaCAN
Gateway
Luma-Net
LumaCAN
LumaCAN
LUMA-NET 3
SAPPHIRE-NET
ACTIVE
ACTIVE
DMX
OUT
IN
DMX512 OUT
DMX512 IN
DMX
10/100
COLORNET
R
T
RS 232
NPDLR-000
COMMUNICATION PORTS
FULL BRIGHT
AUXILIARY
LUMANET
PHASE LOSS
DMX
FAN
R
BRIGHT
SELECT
CANCEL
FULL
SAVE
CLEAR
INDUSTRIAL CONTROL EQUIPMENT
TUALATIN, OR
32300A
R
MADE IN U.S.A.
a-2000
R
TM
LISTED
88H9 C R
20
20
20
MODULE
MODULE
9
8
20
20
20
20
20
20
20
20
20
20
20
MODULE
MODULE
BYPASS
NORMAL
7
6
MODULE
MODULE
MODULE
BYPASS
NORMAL
5
4
3
20
20
20
20
20
20
20
B
MODULE
MODULE
BYPASS
NORMAL
C
PHASE
2
1
CONTROL
PHASE
A
PHASE
10
MODULE
11
12
MODULE
MODULE
NORMAL
BYPASS
20
20
20
20
20
20
SectorNet
Ethernet
Luma Graphics
Luma Scheduler
Note: LumaCAN Gateway used with GreenMAX only may use bacnet/IP direct to GreenMAX Cabinet
NPCDLR
A2000
BACnet/IP
8. DISPLAY MESSAGES
WEB
VERSION