eXtreme
®
Cat 6A Connector Termination Continued
4
Use your fingers to carefully seat wires into the IDC slots.
Maintain wire pair twisting to within 1/2" (13 mm) of the IDC.
Set a 110-style impact tool to low and position it perpendicular
to the connector. Seat and trim the cable one pair at a time to
prevent crushing the inside pairs (Figure C).
5
Place the Cone of Silence
®
over the terminated wires for secure
connection and exceptional Cat 6A performance (Figure D).
eXtreme
®
CAT
6A
eXtreme
®
CAT 6A
Figure C
Figure D
Use the punch down puck to terminate the jack first, then install into a patch panel or wallplate.
|