P a ge 2
INSTALLATION
HAI CONTROLLER
RED
Y
EL
LO
W
B
LACK
G
REEN
FIRE
EVENTS
CANCEL
MESSAGE
MENU
AUX
SETUP
BUTTONS
STATUS
CONTROL
SECURITY
ALL
TEMP
POL
GND (GROUND)
B / GREEN
A / YELLOW
ZONE (-)
ZONE (+)
FOR EXAMPLE: JP2 MUST BE SET TO "458" WHEN SERIAL
INTERFACE 2 (J2) IS USED FOR ACCESS CONTROL.
WHEN A SERIAL INTERFACE IS CONFIGURED FOR ACCESS
CONTROL, THE CORRESPONDING INTERFACE JUMPER
(JP1-JP5) MUST BE IN THE "485" POSITION.
RED
B
LACK
G
RA
Y
O
RA
NG
E
HAI MODEL 83A00
12VDC POWER HUB
P
O
W
E
R
P
AC
K
DC
O
U
T
P
U
T
:
19
V
M
AX
72
W
A
C
I
N
P
U
T
:
110
-230
VO
L
T
S
P
AR
T
N
U
M
B
ER
:
AC
-C
1
0
12VDC
GND
GND
12VDC
GND
12VDC
75A00-1 ACCESS
CONTROL READERS
OMNI CONSOLES OR
OMNITOUCH TOUCHSCREENS
RED WIRE TO +
BLACK WIRE TO -
YUASA NP7-12
OR EQUIVALENT
12V 7AH
BATTERY
1. GROUNDING
Each Pow er Hub MUST be grounded to the controller.
The LEVITON controller and LEVITON
Power Hub(s) must be grounded together to prevent any current from flowing through the RS-485 data bus
(connections A and B). If not grounded properly, damage could occur to the LEVITON controller, LEVITON
Power Hub, Access Control Card Readers, Omni Consoles, and/or OmniTouch Touchscreens.
Connect the “GND” terminal on the LEVITON Power Hub under the section marked “CONTROLLER”, to one
of the “GND” (ground) terminals on the LEVITON controller (See – Figure 1).
HAI CONTROLLER
HAI MODEL 83A00
12VDC POWER HUB
Figure 1