Power Hub 

Cat. No. 83A00-1

Installation Manual

WEB VERSION

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание 83A00-1

Страница 1: ...Power Hub Cat No 83A00 1 Installation Manual WEB VERSION www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ind into this product through openings as they may touch dangerous voltages Never install communications wiring or components during a lightning storm use in wet locations Never touch uninsulated wire...

Страница 3: ...osures 83A00 2 It is supplied with a sealed Power Pack which provides power to the LEVITON Power Hub Features 1 Connections for any 12VDC devices up to 5 Amps total 2 Connections for the following LEV...

Страница 4: ...OMNITOUCH TOUCHSCREENS RED WIRE TO BLACK WIRE TO YUASA NP7 12 OR EQUIVALENT 12V 7AH BATTERY 1 GROUNDING Each Power Hub MUST be grounded to the controller The LEVITON controller and LEVITON Power Hub...

Страница 5: ...municate on a different communications bus Connecting Devices of the Same Communications Type For example if all connected devices that communicate with the LEVITON controller consist of 75A00 1 Acces...

Страница 6: ...Switch SW1 must be in the DISCONNECT position See Figure 4 DEVICE 1 DEVICE 4 75A00 1 Access Control Readers must be connected on the first row DEVICE 1 DEVICE 4 DEVICE 5 DEVICE 8 Consoles and or OmniT...

Страница 7: ...lid 2 2 207 22 stranded 1 1 381 22 stranded 1 1 95 18 solid 1 1 1000 18 solid 1 1 261 18 stranded 1 1 963 18 stranded 1 1 241 16 solid 1 1 1000 16 solid 1 1 415 16 stranded 1 1 1000 16 stranded 1 1 38...

Страница 8: ...ure 5 Connect the supplied 4 conductor reversed modular cable gray cable between one of the modular connectors J301 or J302 on the Power Hub and a serial port J2 J5 on the LEVITON controller See Figur...

Страница 9: ...mina Pro controller if additional power is needed to control the required Access Control Readers and connected locks or if there are long distances between Access Control Readers and the LEVITON contr...

Страница 10: ...L WHEN A SERIAL INTERFACE IS CONFIGURED FOR ACCESS CONTROL THE CORRESPONDING INTERFACE JUMPER JP1 JP5 MUST BE IN THE 485 POSITION CONTROLLER MODEL 83A00 12VDC POWER HUB Figure 7 Gray reversed Cable Bl...

Страница 11: ...e of the 24 gauge conductor in the Cat 5 cable for power 1 for positive and 1 for ground the maximum distance between the controller and the touchscreen is 113 feet 2 The distance between the Power Hu...

Страница 12: ...REENS AND OR Figure 8 Connect the terminals labeled A and B under the section marked CONTROLLER on the Power Hub to the terminals labeled A and B under the section marked CONSOLE on the LEVITON contro...

Страница 13: ...NNECTIONS The supplied Power Pack is used to power the LEVITON Power Hub An AC power outlet should be located within 5 feet One or two sealed rechargeable batteries not included can be used to backup...

Страница 14: ...nstalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Страница 15: ...to which the receiver is connected Consult the dealer or an experienced radio TV technician for help LEVITON LIMITED WARRANTY Leviton warrants to the original consumer purchaser and not for the benefi...