background image

 

 

  

 

IGP-0101 

 

Industrial Gigabit POE Injector, 802.3at PoE+, 36W 

User Manual 

 

 

Содержание IGP-0101

Страница 1: ...1 IGP 0101 Industrial Gigabit POE Injector 802 3at PoE 36W User Manual ...

Страница 2: ... is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE MARKING This equipment complies with the requirements relating to electromagnetic compatibility EN 55022 class A for ITE the essential protection requirement of Council Directive 2004 108 EC...

Страница 3: ...ps speed transmission recommend maximum cable length less than 90 meter is more desired POE signal attenuates every meter the built in transformer allows the attenuation to reach 100 meter long to follow IEEE802 3af at standard the higher quality of PD you connected to the more reliable the network will be When connect to a poor quality PD it can not generate strong signal to send to remote switch...

Страница 4: ...Rail Bracket x 1 Wall mount bracket x 2 4 pin Terminal Block x1 Installation package This unit can be installed by din rail mounted or wall mounted Din rail brackets and wall mounted bracket are included Connecting procedure STEP 1 Take out 4 pin terminal block located in the included mounting kit package STEP 2 Connect power wire to V1 or Connect V2 SW as shown above STEP 3 Plug into terminal blo...

Страница 5: ...de A Green LED ON For End Span POE power 1 2 3 6 LED indicator PW Power 1 Power 2 NOTE Mode B Green LED is only for Mode B End Span model with pin assignment 4 5 7 8 This LED will not lit on for this model ...

Страница 6: ...t 5e Cable EIA TIA 568 10 ohm 100m Protocol CSMA CD LED PW1 power 1 Green ON power good OFF power failed PW2 power 2 Green ON power good OFF power failed POE ON POE Normal working FLASH Overload OFF NO POE power detected POE Pin Assignment Mode A model V V V V for pin 1 2 3 6 Reverse polarity protection Present Overload current protection Present Power Supply 2 Redundant power source 48V 56V VDC P...

Страница 7: ...nsing Storage Temperature 40 85 MTBF mean time between failure 510 304 hrs MIL HDBK 217F at 25 C Housing Rugged Metal IP30 Protection Case Dimension L X W X D mm 103 5mmx32mmx81 5mm LxWxD Installation mounting DIN Rail mounting and Wall Mounting Certifications EN55022 24 ITE equipment Safety IEC EN60950 1 EMC EMS CE FCC VCCI EMI FCC Part 15 Subpart B Class A CE EN 55022 Class A EN 50155 EN 60068 2...

Страница 8: ...8 Housing Dimension ...

Отзывы: