Connecting the IT 3820 to the serial PC interface

With TTL-RS232 cable/PIN9 IT 4xxx   Part No. 501 04586

required parts:

1x

501 06 242

IT 3820 SR 0C0BE

1x

501 03 990

Base station ST 2020

1x 

501 04 586

Cable TTL-RS232/PIN9

1x

501 03 989

Power supply unit ST 2020

Procedure:

1.

Switch off the PC.

2.

Connect the interface cable to a free COM port 
(RS 232) on the computer (3) and to the base station 
(2).

3.

Plug one end of the power supply unit cable into the 
base station (4) and the other end into a free power 
socket (5).

4.

Switch the PC back on.

5.

Scan the adjacent barcode. 
The IT 3820 is set to the following transmission parameters: 
RS 232 transmission with 115,200 baud, 8 data bits, 1 stop bit, no parity, terminators <CR><LF>.

6.

Return the IT 3820 to the base station to apply the settings. This procedure is concluded with optical confirmation signals 
(green LED on the ST 2020).

7.

If necessary, adjust the transmission parameters of the used COM port to those of the IT 3820.

Attention!

 

We recommend connecting the IT 3820 directly to a PC or to the MA 21 or MA 41… connector units. If connecting to 
other components, please note that a voltage level range of -14 … +14V is maintained on the data lines!

IT 3820/3820i

Hand-held barcode scanner with Bluetooth data transmission

Содержание it 3820

Страница 1: ...4586 PS 2 cable for IT 4xxx Part No 501 03409 USB cable for IT 4xxx Part No 501 03404 Power supply unit for IT 4x2x Part No 501 03989 IT 3820 IT 3820i IP 41 IP 41 IP 54 Dimensioned drawing Electrical...

Страница 2: ...0 C 60 C Relative air humidity 0 95 non condensing 0 95 non condensing 0 95 non condensing Light source exempt group in acc with EN 62471 Protection class IP 41 IP 54 IP 41 Certifications IEC 60950 1...

Страница 3: ...er A green target line as well as the red illumination should now be visible Now scan a sample label The scanner emits an audible signal to confirm that the label has been read if necessary the data a...

Страница 4: ...t in trigger button Configuration for the Leuze standard protocol To set the Leuze standard protocol you must first reset the scanner to factory settings and then individually define each of the trans...

Страница 5: ...nd the other end into a free power socket 5 4 Switch the PC back on 5 Scan the adjacent barcode The IT 3820 is set to the following transmission parameters RS 232 transmission with 115 200 baud 8 data...

Страница 6: ...ble KB 021 Z to the MA 41 acc to the above pin assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power supply unit to the base station see Connecting the...

Страница 7: ...in assignments 2 Connect the interface cable to cable KB 021 Z Connect the interface cable and the power supply unit to the base station see Connecting the IT 3820 to the serial PC interface 3 Scan th...

Страница 8: ...on ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 409 PS 2 cable Procedure 1 Switch off the PC 2 Disconnect the keyboard 3 Connect the cable for the ST 2020 base sta tion between the keyboa...

Страница 9: ...n be processed further in all standard programs required parts 1x 501 06 242 IT 3820 SR 0C0BE 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 404 USB cable Procedu...

Страница 10: ...20 SR 0C0BE 1x 501 03 990 Base station ST 2020 1x 501 03 989 Power supply unit ST 2020 1x 501 03 404 USB cable Procedure 1 Connect the cable for the ST 2020 base station to a free USB port 2 The scann...

Отзывы: